How to replace a Diaphragm on an Alpha 240p?

Hi,

I have a very very small leak from the DHW Flow Valve on my Alpha 240p.

There is a very small leak from the front bolt on the DHW Flow Valve where the pin is pushed out of to activate the DHW flow microswitch. The water is leaking from the hole the pin is pushed out of.

Would this problem be solved by replacing the Diaphragm? If so, how do I replace it? I can get to the Diaphragm but unsure how to take it off.

Pritesh
June 2009

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Small Flow Valve

Related Questions ...

Mend diaphragm diverter valve heating
1

how to fix a baxi 105e dhw flow problem?

Hi I have a reduced flow to my dhw on a baxi 105e checked and cleaned both cold water inlet and flow regulator... [Read more]
Mend boiler thermistors diverter valve
2

Heating/Hot Water Problems with Ravenheat RSF100ET?

Hi Original problem was not very hot DHW, but burner running flat out. Changed both DHW and CH thermistors, ... [Read more]
Mend boiler leak system pressure
2

brittany combi se 80 hot water fault?

guys, i have the above boiler, and before xmas had a problem where i had no hot water, i called an engineer w... [Read more]
Mend boiler thermostat plumber
2

Flood due to boiler ???

A few weeks ago we noticed warm/hot water pouring out of the eaves of our house, upon inspection we found that... [Read more]
Mend water problem going
3

No water in hot water tank?

Hi there, I have a problem... lol I'm afraid I'm going to err on the side of giving too much information... [Read more]
Mend heating pressure corrosion
2

optima 701 pressure rises when heatings on drops when off?

optima 701 was in when we moved in,we have had a few problems in the past with pressure releif valve needing c... [Read more]
Mend boiler heating faults
2

dose the baxi bahama 100 flow switch have/need a spring inside?

is there suposed to be a small soft spring in the flow switch of a baxi bahama? my radiators are warm only no... [Read more]
Mend boiler radiators combi
6

no flow from combi boiler to radiators?

Baxi Genesis 80 - hot water ok but all radiators cold. When CH is switched on, the system fires up and the... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...