Recent: Windows 11, Dell 5450, JBL Bluetooth headphones?

Mend > Home Heating Systems

Mend Continental Vulcan Pilot Light Boiler Ignite

ignition for pilot light vulcan continental boiler?

I have just replaced the thermocouple however when trying to ignite the boiler found the wire on the ignition switch was shorting. This wire is very thin and difficult to cut back and fit to clips. Any suggestions on a replacement. Instructions on the boilers says remove plug from boiler front and use a taper however I don,t think this is an option as Ithink it will not budge

john.s
January 2009
Anyone know where to get spares for these Vulcan Verona back boilers? Had a look on ebay and google couldnt see anything.

We are having problems keeping the pilot lite on (has gone out twice in last month).

Will be replacing the whole thing in 6 months and we just need it to keep going through this winter.

Looking to buy a new thermocouple to keep it going.

Craig from Surrey
February 2013
Best boiler made as far as im concerned.Whatever you do dont take the glass out as there is a seal at the back of it which could fall to pieces and the glass is prone to crack if you put it back in incorrectly.The big iron bung in the front will come out but it may need a bit of forcing.Now the interesting bit with regards to lighting the boiler.Get either a drinking straw or take a pen refill out and put a match in the end of it.Get someone to push the gasvalve button down but strike the match on a matchbox and push the holder thro the hole as the match attempts to light.This way the flame wont keep blowing out with the wind when you get close to the hole.Get the person to hold it in for 30 secs then let go slowly.It should stay on,but if it doesnt its possible the t/couple has burnt thro.Even these are easy to change on the 45/60 as you do not need to take the burner tray out.

Tony S
January 2009

Automatic Answer

We may have found other answers which could help you.

Click here for Pilot Light Boiler Ignite

Related Questions ...

Mend boiler heating ignition
1

pilot light wont ignite?

I have a Potterton 30e gas boiler and the pilot light wont ignite,
Mend boiler heating ignition
1

how can i ignite the pilot light on a ravenheat boiler?

how can i ignite the pilot light on my ravenheat boiler
Mend gas heating boiler
1

My Morco gas boiler will not stay alight?

Hi all can someone please advise me I have got a morco D61B gas boiler which will not stay alight when I relea... [Read more]
Mend boiler heating pilot light
2

how to ignite voker pilot light?

vokera boiler no piot light how to ignite
Mend boiler heating Vaillant
2

How can I fix my Vailant Eco tec plus 438?

I've recently moved in and inherited the above boiler which worked really well up until this morning. I am get... [Read more]
Mend changed fan pressure
1

how do I ignite my boiler?

Thank you for such a detailed answer, that's very helpful. I have one more question, we have changed the fan,... [Read more]
Mend boiler heating ignition
1

the button beneath the boiler no longer clicks not helping ignite pilot?

I have used the button beneath the boiler 100e Potterton model. When we have had problems sorted in the past a... [Read more]
Mend heating gas ignition
1

thorn apollo boiler no gas coming through ?

changed the thermo coupler but pilot light will not ignite its as if no gas is coming through
Mend boiler ignition gas supply
1

boiler will not ignite?

my baxi solo 50/4rs has stopped working pilot light is in but when the water or heating is requested allthough... [Read more]
Mend boiler central heating gas
1

Worcester 240?

Hi, My Worcester 240 boiler is playing silly buggers. The pilot light is working but the main burner will ... [Read more]
Mend boiler heating ferroli
1

how can i relite my ferrioli boiler ?

How can i get the pilot light to stay on my ferrioli boiler? I have taken the cover off and lit it but it wo... [Read more]
Mend problem hot valve
1

Alpha 240p boiler problem. ?

Hot tap turned on, diverted valve functions and presses microswitch but gas does not ignite. Pilot light is on... [Read more]
Mend boiler central heating igniter
1

Frolli 77FF combination boiler wont ignitenation boiler won't ignite?

The pilot light will not stay alight. When the igniter is pushed the pilot light comes on but as soon as it is... [Read more]
Mend boiler gas valve pcb
1

What is the problem with my Potterton 60e boiler?

Hi I have a Potterton profile 60e on which sometimes the pilot light light's,but the main burner will only ign... [Read more]
Mend boiler heating repair
3

Help needed to fix Myson Apollo 40B boiler?

Hiya,got a Myson Apollo 40B boiler,pilot light gone out wont ignite,what new part do I need,Thanks.

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...