i have the same problem too, again with a combi boiler that gives scorching water from other taps.
i bought a service kit in the hope that there would be a way to adjust the temperature somewhere in the depths of the shower but although i fitted all the new parts, it was basically a waste of time as it seems that there is no way of adjusting the hot water flow inside the unit.
i have tried to all variations of pressures of water coming from the cold mains and boiler to see if that would help but no joy, it can get hot but becomes inconsistent - not good in a shower
the only thing left to do is to swap the hot and cold inlets into the shower around. from taking the unit apart it seems that the temperature knob open and closes the hot water tap, by swapping them around it should operate the cold flow, with the default flow being full-on hot. Not a great solution but cheaper than a new shower if it works
coelodonta
February 2009