Baxi Combi 105 HE Pressure Gauge Fault? Continued ?

Hi b, thanks for your response 'when you say the filling loop letting by' i have checked both taps and both are turned off (cold water inlet/heating return), could there be a fault with the cold water inlet? and if so, is this something that i'm going to have to get an engineer to come out and fix? Thanks Bekki :o)

Bekki
December 2008
if you disconnect the filling loop and the pressure still rises, then you have a problem with the plate heat exchanger. assuming you are topping it up to 1bar and the pressure rises when the boiler is not operating

Paul the gasman
December 2008