Recent: Trayford close coupled toilet?

Mend Vokera Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Click here to mend Vokera home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

Fix stationary fan on Vokera Excell 80sp?

Fan has always been running even when no demand for HW or CH. Boiler fires up ok for both & sounds like the fan runs, but when they go off fan is stationary. Can hear faint singing like a kettle & temp gauge rises. Turning on HW tap seems to reduce this. Pilot stays lit. Had someone look at it but they said fan doesn't need to run all the time. I don't believe them!

Vic
December 2008
yes iain's right, the fan should slow run when no demand to stop the pilot from suffocating. Probably the boiler flow microswitch is broken, or there's a dry joint on the metalclad slow run dropper resistor, or the fan bearings are getting sticky. If the flow switch is bust it could be dangerous, as it might dry fire with no flow.

c
December 2008
pretty sure fan spins slowly on them due to permanent pilot when nothing is demanding.

iain
December 2008

Automatic Answer

We may have found other answers which could help you.

Click here for Vokera Running Boiler

Mend Heating, Home Heating Systems
Click here to mend Vokera home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend Vokera home heating systems