Recent: Fix food processor motor?

Mend Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Find out how to mend home heating systems

Mend > Home Heating Systems

Mend Boiler Pressure Radiator

WHAT TO DO?

got a linea 24 boiler and the pressure keep going up to 3 i then drain water off at a radiator down to 1.5 and after about 12 hours it goes back up.the heating is off so what do you suggest

Michael.Eaton
August 2008
Check filling loop isnt open,if thats ok either exp vessel pipe is choked or faulty expansion vessel.

Chucky
September 2008
If it is not the filling loop passing it is a faulty hot water heat exchanger. Thi is fairly easy to remove and is detailed in the manual.

Ian
September 2008
Sounds like the boiler is filling itself via a dodgy fill loop. Is there a braided hose of sorts attached to the mains cold water and heating pipe? This might be passing, filling the heating system up.

steve
August 2008
Mend Heating, Home Heating Systems
Find out how to mend home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Find out how to mend home heating systems