Pages 4321
Mend gas fuel sit

how to mend Gas Boiler, Glow-worm Fuel Saver 100F with SIT control?

Thermostat has intermitant fault ie it stays open circuit and does not allow boiler to re-light. Main gas valv... [Read more]
Mend potterton netaheat main burner

How to fix a Potterton Netaheat 10/16 Electronic boiler?

The boiler fires ok and the main burner ignites however every 20/30 secs you hear it try and ignite again. whe... [Read more]
Mend rsf combi allow

how can i fix sticky divertor valve on worchestor 280 rsf gas combi?

valve is not diverting to allow water to heat up,this happened about 5 years ago and i replaced valve and sort... [Read more]
Mend gas combi boiler

gas valve trips out ?

Hi I’ve got a Glowworm swift flow 80 gas combi boiler, The pilot light went out, installed a new thermocoupl... [Read more]
Mend glowworm fuelsaver light

Glow-worm Fuelsaver Mk2 - Pilot light won't stay lit?

Hi all, I have the same boiler as Glen (Mk2 30B, 4131304) and seem to be in pretty much the exact same situ... [Read more]
Mend combi boiler keeps cutting out

Worcester Bosch Combi 350 Boiler keeps cutting out?

Hi there, We have the above named boiler and have had 2 WB technicians in this week to look at it and neith... [Read more]
Mend potterton central heating

Potterton Profile 30E keeps tripping on Central Heating?

My Potterton Profile 30E keeps tripping off and requires the reset button to be pressed to restart. This typic... [Read more]
Mend solo pf problem

Baxi Solo 50/4 Wall Mounted PF Burner Shutdown Problem?

My Baxi Solo 50/4 Wall Mounted PF gas fired central heating boiler ignites when the thermostat calls for heat,... [Read more]
Mend Heating, Home Heating Systems

Flame failure device keeps operating?

I have a Glow-worm Space-saver 40B MK 11 boiler. As the pilot wouldn't stay lit, I have recently (last mont... [Read more]
Mend potterton netaheat electronic up

Potterton Netaheat 10/16 Electronic sudden failure to light up?

Can anyone shed any light on this sudden failure, please. Boiler fan runs but gas fails to start. Fan worki... [Read more]
Mend potterton time pilot ignites

How can I fix my potterton 10/16?

I have recently repaced my mercury vapour switch.Second time in 8 yrs. The pilot ignites, but the boiler will... [Read more]
Mend potterton netaheat fire up

potterton netaheat wont fire up?

Hi we have a netaheat 10/16 with the 407676 pcb board when we turn it on the pcb board clicks but there is no... [Read more]
Mend hot water problem

Hot Water problem?

Ferolli Moderna 80E Combi boiler CH works fine. HW is hot for the first 10 seconds or so but then goes luke... [Read more]
Mend potterton 10 16 gas

Potterton Netaheat 10 16 - gas valve noise & vibration?

My boiler activates, lights and runs OK, but as soon as the gas lights there is a noisy vibration from behind ... [Read more]
Mend water shower bath

Potterton Puma 100, pilot light problem?

My pilot light keeps going out, only after water use, shower bath or sink full of water. I can here the gas va... [Read more]
Mend hot water slow

vaillant hot water problems?

got vaillant 828 turbo plus 3y old.hot water slow to cut in sometimes takes 20 mins sometimes 10 secs,have fit... [Read more]
Mend ignite ignition control gas

potterton netaheat 10/16?

my boiler willnot ignite i have change the ignition control and the gas valve
Mend potterton netaheat ignition help

Potterton Netaheat 10-16 Mk2 delayed main burner ignition - help!?

My Netaheat 10-16 Mk2F can have quite a long delay after the pilot has lit before the main burner fires. In co... [Read more]
Mend potterton heating gas boiler

How can I fix my potterton netaheat electronic 10/16?

When I turn my heating on the Gas boiler fires up and I can hear the pump turn on but none of the radiators he... [Read more]
Mend ferroli boiler 10

what could be wrong with my ferroli modena 80 e?

calling for c/h or h/w boiler fires for 10 seconds and goes to lockout reset it and it just does the same coul... [Read more]