Pages 321
Mend boiler heating hot water turbomax central diverter

vaillant turbo max 282e?

Hi i have a vaillant turbo max 282e The problem i am having is that when the boiler is running on central hea... [Read more]
Mend heating plenty hot water
1

No heating but plenty of hot water ?

Here's a strange one. Vaillant VCW 242 EH. Heating cuts out after a couple of seconds but keeps trying to hold... [Read more]
Mend diverter valve fires

vaillant turbomax 242e vuw?

i have had the diverter valve overhauled, now the boiler fires up fine except for the heating which will only ... [Read more]
Mend heating boiler vaillant turbomax

Leak on the pipe leading to the main heating unit?

I have had various problems with my boiler (Vaillant Turbomax) of late and the current one is a leak that has ... [Read more]
Mend boiler heating advise
2

how to fix my boiler?

hi i have just had my diverter valve replaced and now when i run a bath the central heating comes on even t... [Read more]
Mend heating water exchanger pump
6

vaillant ecomax 824e flashing e20,e13,f20. How to fix it?

Thing is, that my boiler (which is vaillant ecomax824e) use to go through these codes e20 and then f 20, or e1... [Read more]
Mend works fine heating

Why is my Vaillant ecoMAX828 so noisy?

The boiler works fine when firing up for central heating, and also for medium demand hot water. However, when ... [Read more]
Mend problem help years stopped
2

Vaillant TurboMax Problem - Help please?

Hi, I have a Vaillant Boiler Turbo Max around 11 years old. Now the boiler has stopped working as it s... [Read more]
Mend vaillant turbo max
2

vaillant turbo max?

only have hot water when heating is on , have changed diaphragm, still same , if boiler on hot water only, and... [Read more]
Mend problem diverter valve boiler
4

Problem with the diverter valve - vaillant turbo max boiler?

My boiler is 13 years old but in good condition so I don't want to replace it. We've replaced the diverter va... [Read more]
Mend vaillant problem diverter
2

Vaillant Turbomax 828 problem?

This is a strage one! I am not sure whether my diverter valve is on the way out or whether something else is c... [Read more]
Mend hot combi boiler
1

vaillant ecotec pro28r, not enough hot water?

hello all, i have vaillant ecotec pro 28r combi boiler, problem is there is not enough hot water but heating i... [Read more]
Mend boiler diaphragm diverter valve
3

How can I replace diaphragm without my instruction manual ?

My Vaillant ( think it's a turbo as has black panel with green knobs as described by others ) is ten years old... [Read more]
Mend problem valve hot water

Possible problem with diverter valve?

I have a Vaillant TurboMax 824e. When running hot water it initially runs warm water then cold then warm then ... [Read more]
Mend vaillant vuw 242
1

vaillant vuw 242?

is my diverter valve faulty on the hot water. the heating flow pipe gets hot when the hot water is running and... [Read more]
Mend valve movement allow
2

Vailant VCW 242EH, Sticking diverter valve?

Hi, the movement on the diverter valve on my Vailant VCW-242EH is not sufficient to allow the microswitch to ... [Read more]
Mend turbomax central heating
1

vailant 242e turbomax and the temp keeps fluctuating?

My central heating is working fine. But everytime we use the shower or the bath tub the water temperature keep... [Read more]
Mend vaillant turbomax central heating boiler
1

Vaillant TurboMAX Plus 824e -No Central Heating. DV ok?

Boiler appears to function normally with plenty of hot water, no fault codes, pressure 1.8bar but I cannot get... [Read more]
Mend hot water vaillant combi boiler
2

How do I fix hot water on the vaillant combi boiler?

the central heating is running well but the hot water has stopped. I was told to change the diverter valve. Wo... [Read more]
Mend vaillant turbomax central diverter
1

vaillant turbomax F23 error keeps coming up when I turn on the central heat?

Th heat exchanger and the diverter valve were changed on my boiler as the hot water and the central heating ke... [Read more]