Mend Heating, Home Heating Systems

How can I solve fault code e33/34 on an ariston microgenus? ?

How do I solve the fault codes e33/34 on my ariston microgenus 28kw condensing boiler? I have changed the air ... [Read more]
Mend Heating, Home Heating Systems

Potterton Netaheat Profile 80e?

The boiler will not fire up when heat is called for. The pilot lights up and remains on with the fan working a... [Read more]
Mend Heating, Home Heating Systems

how can i fix my Britony combi SE?

fan on but does not activate air pressure switch
Mend Heating, Home Heating Systems

Air pressure switch?

air pressure switch problem i think but any advise would be greatful. When both air tube (red/white) are conne... [Read more]
Mend Heating, Home Heating Systems

40 60 80 error on Chaffoteaux boiler MX2 24FF?

I have the above boiler displaying a 40 60 80 error message on the front panel. From the instruction/user manu... [Read more]
Mend D.I.Y, Plumbing

Netaheat failure to ignite?

Netaheat 10/16 Mk 2 has developed a fault. When the boiler is activated either manually or by the timer the f... [Read more]
Mend Heating, Home Heating Systems

Worcester bosch 28si lockout?

My Worcester 28si keeps locking out shortly after firing. I have ruled out primary sensor, dhw sensor, fan ai... [Read more]
Mend Heating, Home Heating Systems

No hot water with Worcester 28Si?

We have a Worcester 28Si and are now getting no hot water at all. It started a while ago. The central heating... [Read more]
Mend Heating, Home Heating Systems

Glow worm ultimate 50ff fan comes on for 3 sec and go's off don't ignite?

If the pressure switch hose is disconnected the fan will run but with no ignition. Pressure switch checks out ... [Read more]
Mend Heating, Home Heating Systems

Potterton 80e boiler air pressure switch is tripping out?

My 14 year old Potterton 80e boiler air pressure switch is tripping out every 3-4 days due to water (I assume ... [Read more]
Mend Heating, Home Heating Systems

How can i fix my combi boiler vokera excell 80sp?

I now know that either the pressure differential switch or the fan has ceased to function correctly on my comb... [Read more]
Mend Heating, Home Heating Systems

f30 on/ off?

tubes ok venturi ok fan ok flue ok how do i check air pressure switch ok !!!!
Mend Heating, Home Heating Systems

How can i fix my ferrolli 77ff combi?

having problems with a ferrolli 77ff. Boiler will not start in hot water or heating mode, fan runs. have chan... [Read more]
Mend Heating, Home Heating Systems

how can i fix my potterton profile 60e won't fire?

tried all the usuall things fan runs, fitted new air pressure switch have got a spark but still no flame ! any... [Read more]
Mend Heating, Home Heating Systems

how to fix Ariston Micro Genus H.E. Boiler?

hi code E 34 comes up on my ariston micro genus H.E. boiler it says in booklet -air pressure switch does not ... [Read more]
Mend Heating, Home Heating Systems

Potterton FF 40 Boiler start up problem?

My boiler will try starting up on the timer. The fan starts and the air pressure switch clicks on for 15 secs ... [Read more]
Mend Heating, Home Heating Systems

I HAVE A FAULT LIGHT ON MY BAXI 80 E?

The fan fault/Blocked flue light is on on my Baxi 80e combi, the flue and fan are fine so I suspect its the pr... [Read more]
Mend Heating, Home Heating Systems

Baxi Combi 80Eco dead?

I have a Baxi Combi 80Eco installed and is less than 3 years old. 10 days ago it packed up, and the engineer w... [Read more]
Mend Heating, Home Heating Systems

Saunier Duval SD623: Flame goes off and on when boiler is on high setting?

For the past few months the boiler flame goes off and then on repeatedly when boiler is on high stting (when h... [Read more]
Mend Heating, Home Heating Systems

vaillant 242 help!?

boiler starts sequence fan runs then goes to lockout,no spark at electrode,no gas getting through,have cleaned... [Read more]