Pages 54321
Mend hot water vaillant turbomax 242e

Intermittent hot water with my Vaillant TURBOmax VUW 242E?

For the past 4 months I have had intermittent hot water with my Vaillant TURBOmax VUW 242E, well rather luke w... [Read more]
Mend hot water shower combi

No hot water from my electric shower since fitting a combi boiler?

I had a combi boiler fitted in November and the same day, my electric Triton T80si shower stopped giving hot w... [Read more]
Mend central water glowworm

High central heating water pressure - (Glowworm swiftsure 100)?

Hi folks, any ideas on this one? My central heating water pressure on the combi boiler keps increasing until ... [Read more]
Mend combi boiler hello years pressure

I have a Ferroli Modena 102 Combi Boiler?

Hello I have had the above comi boiler for the past two years. Over the last five months the pressure keeps dr... [Read more]
Mend heating bit problem help

Which Way to Jump?

CENTRAL HEATING CALAMITY It may sound a bit dramatic, but I have a real problem and would welcome any help ... [Read more]
Mend pressure top duval

Water pressure disappering?

I top my boiler(Saunier duval SD620F) up every day to have found out it is leaking from the over flow pipe out... [Read more]
Mend gauge rises bleed

high pressure on Worcester-Bosch 24CDi boiler?

Pressure on gauge rises very quickly, has even reached past 4 on several occasions. have to bleed radiator/s t... [Read more]
Mend pressure leaking problem

Ferroli 701 losing pressure and leaking?

Hi, I wonder if there is a simple solution to the following problem: The Ferroli Optima 701 loses pressure ... [Read more]
Mend boiler moment system

combi boiler woscter?

I have a combi boiler . At the moment i seem to have to top up the system every morning and during the day a... [Read more]
Mend baxi pressure bled

baxi boiler keeps loosing pressure - no leak?

My new Baxi boiler looses cir. 1bar pressure per day but there is no leak? I have not bled any of the rads an... [Read more]
Mend boiler not working heating hot water

boiler not working for heating or hot water?

my worcester heatslave 9/24 combi will mnot light up for heating or hot water, pressure is ok. just will not f... [Read more]
Mend glowworm hot central

glowworm 24ci?

hot water ok all day long . when i turn on central heating burner ignites warms up to 30-35 c then shuts down... [Read more]
Mend heating combi boiler worked fine

Pressure rising in central heating system?

I have a Ferroli combi boiler which has worked fine for the last 8 years. However it has recently begun to giv... [Read more]
Mend switch day opened

Henry vacuum switch is broken?

i turned the vacuum on one day as usual and when i removed pressure from the switch it went off again. i opene... [Read more]
Mend vokera problem diaphragm

my vokera linea 28 won't ignite?

pressure problem cured by having the pressure diaphragm replaced.it ran ok for a day but now it won't ignite a... [Read more]
Mend pressure boiler constantly

The pressure on my boiler keeps going down and needs constantly topped up?

Once a day the pressure falls to 0 and needs to be topped up to 1.5. There are no obvious leaks at any of the ... [Read more]
Mend triton low pressure light

How do I get my Triton T80si to work when there's a low pressure light?

For some reason my triton shower has completely stopped working all of a sudden. The low pressure red ligh... [Read more]
Mend boiler serviced clean

Potterton Ultra 2 - re-pressurised, but pressure drops within 2days?

We've had the boiler serviced, clean bill of health. Then had a leak from the water cylinder, so that system r... [Read more]
Mend worcester boiler water

worcester boiler refuses to give hot water central heating?

After having a towel rail fitted my boiler was all working then the following day refused to work thus no heat... [Read more]
Mend vaillant central fault

Have a Vaillant Ecomax 824E Boiler?

Central heating put back on after summer break, fault signal E 12 appears. Water pressure guage keeps going s... [Read more]