Mend properly central hot

Glow Worm Swiftflow 80?

Everything works properly when turning on Central Heating and or Hot water when getting in from work. However ... [Read more]
Mend glow pcb main

Glow Worm 24hxi PCB part numbers?

Hi Can anyone tell me what current part numbers relate to the Main PCB and Interface Card PCB on the original... [Read more]
Mend glow worm saver boiler 30

Glow worm space saver 45-60 cutting out?

My boiler cuts out after 30 seconds cutting off main gas valve so lose main burner and pilot. It had a new t/c... [Read more]
Mend glow worm 24 cxi

how can I fix my glow worm ultracom 24 cxi?

The main display is continually flashing showing 888.888 and all symbals are showing. There is no error code s... [Read more]
Mend burner light pilot

Main Burner will not light, pilot on, electrode sparking, 3 led's on?

My pilot lights and stays alight. The electrode continues to spark, however the main burner will not light, wh... [Read more]
Mend main burner pilot light

glow worm hideaway 60 main burner goes out after short time?

pilot light is fine ,pump is circulating,main burner only stays lit for short time then goes out any ideas cou... [Read more]
Mend boiler model pilot

glow worm boiler model economy e50f?

biler pilot comes on but keeps on sparking main gas valve does not open have fitted new spark cable and cleane... [Read more]
Mend main problem turns

no main burner- Glow worm economy + 80F?

Glow worm economy plus 80F. Fan problem fixed- fan now turns. pilot spark present. pilot light eventually ligh... [Read more]
Mend boiler back front

boiler back to front?

i replced the main pcb and the fan on my ikon 23t boiler(all glow worm parts) and when i put it all back toget... [Read more]
Mend worm light pressure

Glow Worm 35f Fuel saver won't light main burn?

I have an old glow worm 35f fuel saver, positive pressure boiler. The pilot lights intermittently but won’t ... [Read more]
Mend will turn off

my glow worm boiler 30cxi will not turn off?

when my boiler is set to turn off by the timing switch, it remains on, so now to turn the boiler off i have to... [Read more]
Mend display lights main

i have 240v to boiler but no display/ glow worm 30cxi?

no lights on the boiler i think its one of the circut boards the main one / controls interface board could you... [Read more]
Mend combi burner hot tap

combi boiler glow worm 24ci?

the burner comes on then goes out every time the hot tap is running.what could be the main cause
Mend glow boiler not

glow worm boiler not fireing up?

i have got a glow worm ultimate 70ff which isnt fireing up.i have replaced the pcb and the fan and all that is... [Read more]
Mend boiler low times

glow worm f 120 ?

boiler comes on modulating on low flame only turn off and on dozen times on stat main flame comes on ?
Mend glow worm saver pilot

glow worm fuel saver f,pilot lights but main burners wont?

my old glow worm fuel saver f lights up on the pilot no problem,but the main burners will not ignite.Was worki... [Read more]
Mend started fan light

Glow worm Ultimate 40FF not firing?

My Glow worm 40FF is not firing up. When started, the fan runs and the pilot light ignites but the main burner... [Read more]