Pages 1110987
Mend vokera maxin hot

Vokera Maxin 28e combi boiler, DHW runs hot and cold?

A few months ago DHW temperature started to fluctuate mildly between hot and warm. This problem got worse so a... [Read more]
Mend fault heating seconds

Morco Gb24 showing F2 fault?

When you switch heating on burner runs for 6 seconds then goes out for 15 seconds and shows F2. Then F2 goes o... [Read more]
Mend boiler works set

Baxi Solo 3 50 PF Boiler - Only works when the hot water is set to 'on'?

Hi, I have a Baxi Solo 3 50 PF boiler. At the moment it is only working for hot water (which it doesn't se... [Read more]
Mend intermittent boiler runs

How can I solve the intermittent fault on my potterton profile 40e?

Once started up the boiler runs ok until it is shut down by the time switch or the room thermostat. When the t... [Read more]
Mend firebird s 50 90

Firebird - S 50 - 90?

I have a Firebird-S 50-90 ... He works all the time very well but now he suddenly stop, and the red RESET butt... [Read more]
Mend ariston he genus boiler

How can I fix Ariston HE genus Boiler?

Boiler Fault E33.... have changed air pressure switch and fan fault still exist the fan does not switch on to... [Read more]
Mend Kitchen Appliances, Electric Cookers

Continuously bn (burning) ?

Hi, I am using Schott Ceran Cook top panel. One of its burner is continuously burning. Its not possible to mak... [Read more]
Mend central heating fault

central heating fault?

have potterton promax he plus I switch on central heating, burner light comes on for 10 seconds then goes off... [Read more]
Mend isar he again problem

Isar HE 35 again problem?

Hi Last winter (thankd to this forum) I did replace diverter valve, temp gauge and water pump and spring come... [Read more]
Mend boiler set call

Boiler sometimes doesn't fire up have to flick reset switch main 30he?

Have to set stat to call for heating to get hot water to fire up burner
Mend error fan problem

Glowworm Micron 50FF, software error?

We have a Glowworm Micron 50FF installed. It was not working, apparently a fan problem. Engineer changed fan t... [Read more]
Mend hour heating boiler

oil burner does not stay off after hour is up?

burner comes on when it shouldent and keeps heating on i have to switch off boiler outside
Mend burner heat 15

how can i fix my burner logic heat 15?

my burner showing code l2 tried the reset switch did not work what do I need to do
Mend switch burner water

how to switch on the gas burner on my carver cascade water heater?

How do I switch on my heater to use gas. .
Mend Heating, Home Heating Systems

when the oil burner starts up the rcd trips out?

my worcester bosch greenstar utility 18/25 boiler will not fire up instead the rcd trips out. I switch the boi... [Read more]
Mend switch turned spark

I have a Electrolux RM4401 3way fridge?

When the switch F in the manual is turned on to spark the gas burner the fridge starts up but the switch F sti... [Read more]