Recent: Matsui ct-111ss?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Burner Central Heating

Free repair help

We have 134 questions about mending 'burner central heating'

How to mend ... Burner Central Heating

Pages 54321
Mend hot heating replacing
2

how can I fix Combi Ideal Response 120. No hot water/central heating?

I am trying to fix an Ideal Response 120. After replacing the Limit stat, when DHW is turned on initially mach... [Read more]
Mend ignite central heating
1

Ideal boiler ff250 will not ignite?

I have an Ideal FF250 boiler that will not ignite the gas burner although the controller is asking for both Ce... [Read more]
Mend central heating fine
1

Worcester 9.24 electronic Boiler H/water prob?

Hi The central heating works fine but recently the burner would go off a few minutes after turning on the h... [Read more]
Mend hello central heating temp
1

Problem with Ravenheat csi85T?

Hello When central heating reaches temp burner cuts off but then continues to ignite then go out until i turn... [Read more]
Mend boiler keeps cutting out
3

boiler keeps cutting out?

my "heatline compact boiler" goes through ignition sequence but will not fire for either central heating or ho... [Read more]
Mend hot water taps year
4

Baxi 105e. Central Heating working, no hot water through taps !?

Hi everyone. I've got a 3 year old Baxi Combi 105e, that, for some reason last night, got low water pressure a... [Read more]
Mend start potterton kingfisher
1

Why does the main burner(CF 40 furingas) start roaring at times?

Ref above my boiler is a Potterton Kingfisher free standing open flue gas fired boiler (approx 25 years old) a... [Read more]
Mend loud burner boiler
4

LYNX 2 LOUD SQEAL LIKE THE PUMP BUT COMING FROM INSIDE WERE BURNER?

WHEN BOILER FIRES UP ON HOT WATER OR CENTRAL HEATING LOUD NOISE LIKE THE PUMP IS COMING TO A HAULT THEN FLAME ... [Read more]
Mend fault vaillant turbomax
1

Intermittent Fault Vaillant turbomax VUW 242E?

How can I fix my Vaillant Turbomax VUW 242E? My boiler is 8 yrs old. The flame indicator illuminates but th... [Read more]
Mend puma 80e combi
1

Potterton Puma 80E Combi overheats and trips out on hotwater cycle?

When the hot water is adjusted or moved from its minimum setting the boiler trips out. Why? Almost every part... [Read more]
Mend solo pf problem
10

Baxi Solo 50/4 Wall Mounted PF Burner Shutdown Problem?

My Baxi Solo 50/4 Wall Mounted PF gas fired central heating boiler ignites when the thermostat calls for heat,... [Read more]
Mend boiler starts running
3

Potterton Puma 80 firing on and off?

My Potterton Puma 80 comi boiler starts firing on and off after it has been running for a few minutes - both h... [Read more]
Mend fault combi heating
2

Fault with Ravenheat Combi boiler (heating goes off)?

I have a Ravenheat Combi boiler which provides hot water ok. However, when the central heating is switched on,... [Read more]
Mend rsf turn water
3

hi i have a ravenheat boiler rsf 84et not firing up?

when i turn on the hot water or the central heating,the fan starts up and the pilot egnition fires and lights ... [Read more]
Mend come out cool
1

Why does the hot water on my Ravenheat boiler sometimes come out cool?

A Ravenheat 820/20 combi boiler, had diverter valve diaphragm replaced last year as it had perished, now occas... [Read more]
Mend diverter combi boiler problem
6

do i need another diverter valve for my alpha 280e combi boiler?

My alpha 280e combi boiler has a problem with the hot water temperature, it fires up ok starts to heat the wat... [Read more]
Mend glow worm swift flow 80
11

How can I fix my Glow Worm Swift Flow 80 ?

How do I check that the Fan is working ? How do I know if the Thermocouple isn't working ? My daughter's... [Read more]
Mend heating ariston water
1

heating goes off after a few minutes?

I have an Ariston Euro Combi Boiler. Hot water is ok. However the central heating does not come on or goes off... [Read more]
Mend ch water turbomax 824e
3

CH OK no HOT WATER on Vaillant Turbomax Plus 824E ?

Central heating works fine, but not hot water on any taps. When I turn the taps warm water coming for few SECO... [Read more]
Mend switched diverter valve
3

Puma 80 overheats and shutsdown when DHW switched off?

This 8 year old Potterton Puma 80 has had first a new diverter valve fitted, and now a circuit board, but stil... [Read more]
Pages 54321

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.