CH OK no HOT WATER on Vaillant Turbomax Plus 824E ?

Central heating works fine, but not hot water on any taps. When I turn the taps warm water coming for few SECONDS and then COLD Water. Burner is ON when DHW demand, cleaned main heat exchanger - no luck.

could it be microswitch ?

Please help

Mu John
November 2005
will definastely be the diverter valve, im doing one tomorrow. get it done by a gas safe engineer

gas safe boiler man
March 2010
just check if any of the radiators ( the closest one to the boiler first) are getting warm when you are running the hot water. If so then it is probably the diverter valve. I changed mine when i had these symptoms and everything was ok. Easy to change as well. A few for sale on ebay at the moment

stu
January 2007
yes i got same poblems
any luck

anil
November 2006

Automatic Answer