Mend fan run will switch off

Baxi 105e instant fan continues to run and will not switch off?

Hi there. I have a Baxi 105e instant boiler. When heating DHW it goes through correct sequence as described... [Read more]
Mend lighting pilot combi boiler light appear

Glow worm 75 is not lighting - pilot & fan are ok??

I have a glow worm 75 combi boiler that will not light, the pilot light & fan appear to be running fine but no... [Read more]
Mend main burner keep

why does my main burner keep constantly lighting and going out?

Hi I have a baxi solo wm 40/pf bolier which keeps constantly igniting then going out. The pilot is lit and the... [Read more]
Mend hello central heating temp

Problem with Ravenheat csi85T?

Hello When central heating reaches temp burner cuts off but then continues to ignite then go out until i turn... [Read more]
Mend baxi solo 2

my baxi solo 2 has stopped working?

the boiler is not starting when asked to start the boiler on led lights and then there is a clicking noice in ... [Read more]
Mend pcb fitted replaced boiler

PCB Glowworm micron 50FF (replacement fitted)?

I have just replaced the PCB on my Glowworm micron 50FF but the boiler does not light. The old PCB appeared to... [Read more]
Mend kingfisher mf off

Potterton Kingfisher Mf. on-off cycling?

Boiler 3 yrs old. At the end the heating cycle there is about 8-10 clicking sounds in say 10 secs with the fan... [Read more]
Mend boiler heating lock

Vokera Maxin24?

The boiler runs ok when on heating. If anyone uses the shower, the water runs cold and boiler goes to lock out... [Read more]
Mend intermittent light boiler

Ariston Euro Combi SX20 MFFI - Intermittent Pilot Light Failure?

My boiler pilot light goes off and on intermittently. The fan seems to stay on but the pilot light doesn't. ... [Read more]
Mend light showing problem

Potterton Profile 50e struggles to light?

Hi, Our Potterton Profile 50e Boiler is showing the following problem: When the system switches on (heat... [Read more]
Mend ravenheat problem combi

Ravenheat CSI 85AT boiler tripping problem?

Ravenheat condensing combi boiler CSI 85AT fault? My 1.5 year old boiler has developed a random & intermitt... [Read more]
Mend problem boiler pcb fan

Glow-worm kfb 50 problem?

my boiler shows only 2 neon lites on pcb and the fan will not kick in I fear its the fan assembly unit as the... [Read more]
Mend ravenheat boiler 15

Ravenheat condensing combi boiler CSI 85AT fault?

My 1.5 year old boiler has developed a random & intermittent tripping fault, in both modes of heating (i.e. CH... [Read more]
Mend potterton netaheat electronic up

Potterton Netaheat 10/16 Electronic sudden failure to light up?

Can anyone shed any light on this sudden failure, please. Boiler fan runs but gas fails to start. Fan worki... [Read more]
Mend baxi 105 he

Baxi 105 HE?

Fan LED light coming on, no hot water or CH, sometimes lights up then goes off again, the last two days have b... [Read more]
Mend worcester rsf boiler

PCB for worcester 35cdi mk2 rsf boiler?

Following the fault dianostics, given a fast flashing red lamp, on J flowchart in the owners manua (The fan no... [Read more]
Mend friendly format 80e problem

Sime friendly format 80E Intermittent Relight?

I have the same problem as Neil Johnson. Switch on and runs fine, when the temperature has been reached the bu... [Read more]
Mend turns fine apart

Whats wrong with my Boiler ,sime farmat 80c?

Hi there I realy need help with my boiler, everything turns on fine apart from when its about to fire up, w... [Read more]
Mend 50 control board fault

Potterton Profile 50 control board fault?

This was quite an unusually one for me as my normal work is designing in car multimedia systems! A work fri... [Read more]
Mend boiler fault pump

Repair sime combination boiler?

Intermitent fault on sime super combination boiler. Pump running but no power to fan, could it be a pcb board... [Read more]