Recent: Washing programme stops after 3 minutes?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Boiler Ignite Working

Free repair help

We have 146 questions about mending 'boiler ignite working'

How to mend ... Boiler Ignite Working

Pages 54321
Mend ideal boiler coming
1

I have a Stelrad Ideal W Gas Boiler, & last night it decided not to spark?

It seems that the boiler is coming on, the main dial, clock and switch all appear to be running fine, there is... [Read more]
Mend baxi inset boiler
13

Baxi Bermuda Inset 3 (50/5)Boiler wont ignite any suggestions?

I have a Baxi Bermuda Inset 3 (50/5)Back boiler and fire (only 2 1/2 years old). Fire works. Boiler was workin... [Read more]
Mend working heating fan
1

ariston sx20 mffice not working?

when turning on heating or hot water i can hear fan running but no flame. if i remove main front cover with li... [Read more]
Mend oil boiler water
3

worcester heatslave 15/19 oil boiler,no ignition?

I have a worcester heatslave 15/19 oil boiler, i am getting hot water but no central heating, radiators are co... [Read more]
Mend ignite working work
1

halstead combi flashing power light?? won't ignite?

i have a halstead combi boiler and it was working last night i got home from work and went to use the hot wate... [Read more]
Mend boiler wont light up
1

My boiler won't light up?

I have a potterton puma 80e central heating boiler that will not ignite. the electric and gas is working but i... [Read more]
Mend worcester 28i junior
1

Worcester Greenstar 28i Junior stops working?

Hi all I just bought a new house and the previous owner installed the Worcester Greenstar 28i Junior. I went ... [Read more]
Mend button coming turned
1

Why does the red reset button keep coming on when my boiler is turned on ?

my alpha 280e boiler fails to fire up when switched on.. the boiler has gas, water and electric supply. the ... [Read more]
Mend boiler switched hot water
1

I have an Alpha 280E boiler?

The fault I have is intermittent and only happens in the summer when the heating is either switched over to ho... [Read more]
Mend 90 slow start
2

Sime 90 slow start?

My boiler was serviced last December and was working normally. Now it takes up to a minute to ignite when hot... [Read more]
Mend problem light start
1

We have the same problem as Baz but with a Potterton profile boiler?

The pilot light comes on but goes off again. The radiatiors start to get warm and then go cold again. We hav... [Read more]
Mend baxi solo wall boiler second
2

BAXI Solo 2 Wall Mounted Boiler - Main PCB Needed?

Hi I would like a second opinion. My boiler runs perfectly and sounds fine but is failing to ignite the piol... [Read more]
Mend boiler fire appear
1

BOILER WILL NOT FIRE UP,PILOT LIGHT IS LIT?

APOLLO 15/30 BOILER ,BOILER WILL NOT FIRE UP ON DEMAND,PILOT LIGHT IS LIT AND ALL ELECTRICS APPEAR TO BE WORKI... [Read more]
Mend problem system working
2

Problem with my Baxi Bermuda 401?

System was working great, then I serviced the hot water tank in the airing cupboard and replaced the thermosta... [Read more]
Mend boiler heating replaced
5

Ravenheat RSF84ET combi boiler, what's wrong with it??

Hi, no heating or h.w. Corgi plumber replaced 'gasvalve pcb' and 'main pcb' yesterday, got it working, but it ... [Read more]
Mend ideal working classic
1

Ideal Boiler is no longer working properly?

I have an Ideal Classic boiler. I guess it's around 15 years old as its age is comparable with the house. I'... [Read more]
Mend red reset button
1

I have a Protherm 80e that is not working.It is saying F0.What is that?

The boiler will not ignite. I have tried pressing the red reset button but that is not doing anything. I hav... [Read more]
Mend boiler dhw days
5

Is my Fan faulty?

After having problems with my boiler not supplying any DHW or CH the last couple of days i am of the opinion i... [Read more]
Mend potterton suprima working
1

My potterton suprima 30L boiler will not egnite?

The boiler comes on and the fans working, But it will not ignite a flame the red light is on constant and the ... [Read more]
Mend tripped pressure help
2

Sime 100c power tripped pressure ok can't re-ignite?

Hi, Hope someone here can help. My Friends Sime Format 100c combi boiler seems to have tripped. There are n... [Read more]
Pages 54321

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question