Recent: Fix food processor motor?

Mend Baxi 105E

howtomendit.com find out how to mend just about anything.
Categories

Mend Baxi 105e Boiler Valve

Free repair help

We have 55 questions about mending 'baxi 105e boiler valve'

How to mend ... Baxi 105e Boiler Valve

Pages 321
Mend baxi combi radiator boiler

Baxi combi will not restart after changing radiator?

I have a Baxi combi 105E boiler and have fitted a new towel radiator.after refilling system (all radiators ha... [Read more]
Mend baxi 105e boiler valve

Replacing parts in Baxi 105e boiler 3way diverter valve ?

I have cleaned out the scale and gunge and am uncertain of the correct replacement order of the springs and ... [Read more]
Mend baxi turned turn boiler

Baxi combi 105e turned off to stop a leak but how to turn off gas?

i want to make sure my boiler is safe until i track down a plumber. I turned off the boiler at the mains whic... [Read more]
Mend hot water 100

baxi 105e hot water not 100%?

Boiler works ok on ch. When on hw only temp depends on flow rate and although ch is off the radiator in bathro... [Read more]
Mend help baxi 105e

Help with Baxi 105e?

My Baxi 105e has recently developed a problem! On Saturday expansion vessel packed in and leaked. I dried ever... [Read more]
Mend baxi 105e kit

baxi 105e diaphragm kit?

Hi all, i believe there are 2 different diaphragm kits for this boiler, i.e 5111137 and 5111140. is there ... [Read more]
Mend intermittent hot water

Intermittent hot water on Baxi 105e?

Hi,my boiler has developed a fault on DHW supply,when asked for hot water, system fires up runs for 30 seconds... [Read more]
Mend baxi 105e ch fault

how to fix baxi 105e c/h fault?

hi guys /girls, i have just fitted a new diaphragm in differential valve then put it all back togeth... [Read more]
Mend valve baxi 105e heating

How do i replace the o ring on the H/W valve?

Hi, Baxi 105e boiler is whistling when heating is on, if i run hot water tap it stops, have read that it can b... [Read more]
Mend pressure combi 105e

no hot water and pressure valve is on red and water is leakiing outside?

I have installed a baxi combi 105e; serial MBKo451 compno 2478726/00. My combi boiler is playing up. For mo... [Read more]
Mend baxi boiler pressure

baxi 105e combi boiler?

boiler wont modulate when central heating is on causing pressure to exceed 2.5bar, is it the electric safety s... [Read more]
Mend boiler 105e water dhw pressure

boiler?

i have a baxi 105e combo boiler and it is dripping water frome the dhw pressure differential valve at the fron... [Read more]
Mend baxi combi instant

Baxi Combi Instant 105e hot water works but no heating?!?

Hi I have a Baxi Combi Instant 105e. The hot water preheat function works, and so does the normal hot wa... [Read more]
Mend baxi 105e hot water pressure

baxi 105e?

i have no hot water on the ground floor & water is dripping from pressure relief valve pipe,as system pressure... [Read more]
Mend water turn tap fires

domestic hot water problems baxi 105e?

when i turn on hot tap boiler fires as normal the water heats up normally but there is a squeeling noise from ... [Read more]
Pages 321

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question