Mend Worcester Bosch 280 Thermostat Combi Boiler Room

Add a room thermostat to my Worcester Bosch 280 Combi Boiler?

Can i put a room thermostat to my worcester bosch 280 combi boiler, if yes how is it done?

Darren Smith
October 2007
Yes i just did it to mine you need a room stat like from b and q. I used the (T6360)the three wire type . Turn the boiler off at the mains. Mount room stat where you want it about 1.5 meters up wall. Using 1mm twin and earth cable to connect from stat to boiler. Lift off front white cover on boiler by pulling out at lower part and lifting off. Undo two screws holding the lower panel, tilt it forward to reveal circuit board. To the far right of board there is a connector with 5 screw connections in. The top 1 + 2 are for a frost stat you dont need these for room stat ,just the lower three . Numbered from the top 1,2,3,4,5. Three and four should have a link connecting them together. Remove this link ,this is where you will connect your three wires to.
Inside the stat i wired brown wire to number 1, Blue wire to number 2 and the earth wire to number 3.
Route the cable to your boiler then it goes into the lower cover after you remove the two screws from inside the lower cover looking up under it. There are some plastic hole blanks which you will need to make a hole into one to put the cable through then blue wire goes to the bottom of the connector block (number 5) then the earth wire goes to the next one up (number 4) then the brown wire goes to the one above that (number 3).

Adrian
February 2011
can i fit a honywell dt90e roor stat

ivor cottrell
November 2010

Automatic Answer

We may have found other answers which could help you.

Click here for Thermostat Combi Boiler Room

Related Questions ...

Mend thermostat boiler fault
1

Which model room thermostat do I need?

I have a Worcester Green Star 37cdi combi boiler. The room thermostat controller is showing an E1 fault so I ... [Read more]
Mend boiler heating thermostat
1

fitting a room stat?

can i connect a seperate room thermostat to a ferroli 77 ff combi boiler
Mend thermostat boiler wireless
1

Programming Honeywell CM921?

Hi: The heating engineer installed this unit during installation of a new boiler. This is a 1 day wireless pro... [Read more]
Mend Danfoss Thermostat Combi Boiler
3

wiring danfoss 103 timer to a danfoss ret230p thermostat?

I have a Sunier Duval SD 620 combi boiler and have a Danfosse 103 timer ~ old but reliable ~ Im fitting a Danf... [Read more]
Mend combi boiler central heating thermostat
3

My boiler has no thermostat connected. This is surely wrong?

I have just rented a house and found that there is no central heating thermostat connected. The landlord assur... [Read more]
Mend central heating combi boiler ravenheat
1

Cental heating not working on RSF 84 ET combi boiler?

We have a Ravenheat RSF 84 ET combi boiler. DHW is working fine but cannot get the central heating to work. ... [Read more]
Mend combi boiler thermostat heating
2

How can I make my combi boiler recognise the room thermostat ?

I have a combi worcester boiler installed by british gas. It has been fine until the batteries ran out in the ... [Read more]
Mend combi boiler gas boiler heating
3

Ferroli combi not responding to thermostat?

I have a 3 year old Ferroli combi gas boiler. A couple of years ago it stopped responding to commands from the... [Read more]
Mend boiler combi boiler thermostat
15

How can I fix my Baxi Combi 105HE boiler?

The heating has suddenly stopped working today. We have a combi boiler and the hot water still comes on insta... [Read more]
Mend combi boiler heating temperature control
2

Ariston Microgenus 27 remain ON all the time?

I have noticed the my combi boiler Ariston Microgenus 27 seem to remain ON at all times ?............ is this... [Read more]
Mend thermostat boiler wireless
2

Can I fit a wireless Danfoss thermostat to a Worcester 28 CDi Boiler?

I have a Worcester 28 CDi RSF Combi boiler running solely on it's own thermostat. I also have wall-mounted wir... [Read more]
Mend thermostat room set
1

Can I install a thermostat to combi boiler?

I have a Vokera combi boiler (12 years old I think) but it doesn't have a room thermostat. It can be set on or... [Read more]
Mend wire room thermostat
3

How to wire a room thermostat?

Hi, i have a Ravenheat csi 120 (t) low nox combi boiler but there is no room thermostat so i have bought a Sal... [Read more]
Mend thermostat boiler heating
1

How can I fit a room thermostat to my Ferroli Combi boiler?

I'm looking to fit a room thermostat in our flat. We currently have a Ferroli Combi boiler and are not sure ho... [Read more]
Mend boiler radiators thermostat
2

Should the flue from my Ariston A30 MFFi be dripping? (and other questions)?

I have recently had an Ariston Combi A30 MFFi installed. The flue is located a good height above my downstairs... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...