Ferroli Modena 80 E
The boiler keeps cutting out due to low water level. It is daily well topped up. It then works OK. There are no signs of leaks.
Thanks for any advice.

Chris
February 2005
how many radiator can i run with a ferroli 30B boiler combine i have 4 small 3 double 1 lager 3med and t
taken 40 to 60 min to heat all of them is it about right the boiler is only 3 years old

paul
November 2011
the Pressure Relief Valve is faulty/dirt or grit on seating on prv/
pressure vessel on boiler is faulty / check radiator valves are not leaking from the top of the valve when system is cold

frank
November 2005
i hav the same problem on a worcester boiler and its none of the above problems ! i think its to do with the auto vent system so if anybody knows anything about that plese drop a line, will post any sulotions i find that work !

gary
February 2005
Thanks for the useful reply
The overflow pipe could be the culprit.
What would cause that?
I know that when the boiler is topped up the excess goes straight through and out through the overflow
But isn't this because there is too much water in the system
Not too little
Thanks again for the advice

Chris
February 2005
preasure drop is usualy caused by a leak of sum sort you say you dont have one? but is there a chance it could be under a suspended floor which you would not notice?
another place to look is the safty discharge pipe (blow of pipe) which comes out the bottom of the boiler on the left hand side and should go outside the building usualy drilled through the wall sometimes this may pass causeing the water leaking to go unnoticed.

mail back if this doesnt help coxheadj@aol.com

ian
February 2005

Related Questions ...

Mend boiler heating leak
1

Ferroli Optimax HE Plus Leaking?

Water dripping from under the boiler onto my kitchen top. I have dried the area with paper towels and looked ... [Read more]
Mend boiler heating leak
3

how do i fix my boiler?

my boiler works on heating but not hot water it had a leak from plastic valve on flow meter this has been repl... [Read more]
Mend gas leak valve
1

what is the cause of a gas leak around the inlet valve on myferolli opti he?

i came home yesterday to find smell of gas upstairs transco came out and did sniffer test and found a gas leak... [Read more]
Mend boiler leak home heating
1

Leak on ferroli boiler from pump air vent?

I have just bought a repossesed house with the ferroli boiler, which was fully drained including the radiators... [Read more]
Mend boiler leak heating
3

Ferroli Optima 701 boiler will not fill with water?

The pressure on my boiler dropped suddenly to zero. Opened the tap and refilled to 1.1 and then shut of the in... [Read more]
Mend boiler heating fault code
2

ferroli optimax 25c. empty boiler?

re.ferroli 25c. no hot water. no.heating. gauge shows zero. have to refill every morning. fault code f37. can... [Read more]
Mend ferroli boiler working
1

Where is the isolation valve?

I have a ferroli optima 700. I recently had a leak which stopped my boiler from working completely (no hot wa... [Read more]
Mend boiler pressure leaking
1

ferroli combi boiler leaking from relief valve?

a new valve has been fitted but it is leaking also . could extra pressure in the boiler caused by heat cause ... [Read more]
Mend boiler pressure expansion vessel
1

ferroli f24 pressure drops?

Hi i have a Ferroli F24 Combi boiler and the pressure keeps dropping, there seems to be no leak on the system ... [Read more]
Mend boiler ferroli 77
1

Boiler pilot system Ferroli Combi 77 FF?

boiler not firing up after proper ignition sequence is followed, pilot extinguishing itself after ignition but... [Read more]
Mend boiler leak pressure valve
2

Ferroli Falcon II - Pressure valve problems? Please help!?

Hi, for months we've been topping up the boiler, and now it's every 2 days or so, and usually drops when I've ... [Read more]
Mend boiler leak pressure
1

leaking pipe? Ferolli boiler new in 1993?

Our Ferroli boiler's pressure keeps dropping and we have been told we have a leak (not in the boiler itself) ... [Read more]
Mend boiler pressure leak
2

How can I fix my ferroli combi boiler?

My 2 year old Ferroli F24 combi boiler keeps losing pressure. I refill it to 1-2 bar, however the pressure ke... [Read more]
Mend boiler pressure heating
4

pressure keeps dropping on ferroli gas boiler?

i have a ferroli modena combi gas boiler. a couple of weeks ago the pressure dropped to 0.5 bar so the heating... [Read more]
Mend boiler pressure leak
1

my boiler is loosing water pressure & stops the heating?

Once a week I have to use the tap on the boiler to build up the pressure til the gauge goes from 0 - 1 bar. i... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...