Recent: Will I need to replace my garden tap?

Mend > Home Heating Systems

Mend Smith GB100W Light Going Good

Why would the pilot light keep going out on Smith GB100W Natural Gas Boiler?

Good Morning,

Yesterday morning we woke to no heat after installing a brand new heater (replaced twice in two years due to floods). Since yesterday we have been going down into the basement and relighting the pilot light every 40 minutes as well as trying to fix the problem.

The Rollout Switch, High Limit Switch and Spill Switch are operating correctly, we have tested for carbon monoxide and it has no filter.

However the Gas Valve seems to be missing a screw on the intake side (we can't find it). Can you think of anything else that could be causing this?

Thank You
Cindy-lu
email: sar883@hotmail.com

(Model VR8200 or VR8300)

Cindy-Lu
January 2007
I am having a similar problem. I have been told that it could be a faulty thermocouple (the device that in conjunction with the pilot light keeps the gas flowing to the boiler. If the thermocouple fails the gas valve will close (as a safety mechanism) and the pilot light will go out. I guess they are relatively cheap to fix (the part is like $6) Also it could be caused by a draft in your basement or backdraft coming down the chimney that is actually blowing out the pilot light. Good luck

Jason
January 2007

Automatic Answer

We may have found other answers which could help you.

Click here for Light Going Good

Related Questions ...

Mend boiler heating fault
2

How can I stop my Ravenheat CSI 85B tripping out?

I had a new Ravenheat CSI 85 B T installed today. It worked for the plumbers who installed it - they left and ... [Read more]
Mend boiler heating glowworm
5

Having problems with my Glow worm Boiler?

Since the gas ran out yesterday in my house the boiler wont work properly , Ive since put gas in but the boile... [Read more]
Mend help combi boiler red
17

Help with SABRE HE25 COMBI BOILER- RED LIGHT OF DEATH?

Hi, Im after some advise and hoping someone can maybe help me (please!) I have a Sabre HE25 Combi Boiler (sa... [Read more]
Mend water problem going
3

No water in hot water tank?

Hi there, I have a problem... lol I'm afraid I'm going to err on the side of giving too much information... [Read more]
Mend combi central heating pressure
4

Problems with Ravenheat Combi RSF Fanned?

Boiler has no markings on, but have manual that says... Fanned Combi RSF 84E - RSF 100E RSF 84ET - RSF ... [Read more]
Mend heating vaillant no heat
1

Now to fire up the Vaillant!?

Thank you John for your advice. That worked nicely, water pressure is good, the electrics are turned on, the p... [Read more]
Mend boiler central heating gas flame
4

My CH boiler keeps blowing out when its windy outside!?

Hi, I hope someone can help me with this one. I have an old Baxi Wm 381 RS CH boiler in a house we just moved ... [Read more]