Recent: Safely remove screen protector from a Macbook Air?

Mend > Home Heating Systems

Mend Ideal 15ff Boiler Fan

ideal slimline 15 ff?

hi i have a slimline ideal boiler 15ff the fan has been changed and when the cover is fitted the flames start to bounce as if they are being starved of air. when we take it off it lights up and works fine until we replace main cover then the flames start to bounce again after a few seconds.

dave ( fife scotland)
January 2015

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Ideal Boiler Fan

Related Questions ...

Mend 15 stops start
1

Fan tries to run every 15 seconds then stops immediately?

I have an Ideal logic system boiler which will now not ignite. The fan tries to start every 15 seconds then s... [Read more]
Mend boiler heating repair
2

Ideal Classic FF260 boiler - fan full of water?

13 years old and on its last legs according to British Gas. Fan has been noisy now boiler won't light. Suspect... [Read more]
Mend heating thermostat engineer
3

Ideal Classic no heating but have hot water?

HI all, i have just found this fabulous site, I wonder if anyone could help as right now things are just miser... [Read more]
Mend heating boiler repair
1

ideal classic gas boiler?

noisy fan, how do you get at it
Mend gas boiler heating fault
3

Boiler switches on/off every minute when heating hot water?

Hi. I need some advice please. I'm renting a property which has an Ideal Classic LX FF & FF Fanned Flue Gas... [Read more]
Mend boiler temperature motor
1

Ideal (Henrad) SE40FF boiler fan locking?

I have a Ideal SE40FF boiler. When the boiler is cold, the fan spins and the boiler runs just fine. However,... [Read more]
Mend boiler heating relight
1

My IDEAL Classic ff340 Boiler not working?

Hello I clean the fan as suggested and although it lit up, the flames went after about 20 secs. did not rel... [Read more]
Mend boiler heating pcb
1

Noisy Ideal Elan RS 60 Boiler?

Hi all, I have an Ideal Elan RS 60 Boiler. It sounds as if the fan bearings are worn and the fan is fouling th... [Read more]
Mend classic lxff ff fanned boiler boiler
1

Classic LXFF FF Fanned Flue Boiler, part number for a fan for this boiler?

The boiler is squeeling, which I presume is the flue fan assembly bearings. So that I can send for the correc... [Read more]
Mend boiler gas engineer fault
2

classic fan flued boiler unreliable &cuts out ?

Classic boiler been very reliable but started to cut out having started and have to press reset button to star... [Read more]
Mend boiler heating thermostat
6

Ideal Elan 2 40F boiler?

Hi all, I have an approx 15 year old Ideal Elan 2 40F boiler which was in the house when we moved in. A few... [Read more]
Mend pump boiler lock
1

ideal response 120?

pump runs, fan runs but boiler fails to light and goes to lock out. also seems to be a leak on pressure vessel
Mend boiler heating seized
4

ideal classic ff260 fan on top partial seized?

The boiler will not fire up until i flick this fan as hard as i can Can I replace this fan if so where do I ... [Read more]
Mend boiler heating troubleshooting
2

ideal classic nf50?

boiler lights up and runs for approx 2mins then goes out is it the fan ?
Mend heating hot water pilot light
1

no heating/ideal classic lxff ?

have a ideal classic boiler.no pilot light no heat fan do's not kick in when turned on.little plastic fan on t... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...