Mend 80 Gas Boiler

E type ideal standard rs 80?

Since recently having a new gas valve fitted the boiler seems to bang loudly when firing up. Sometimes extremely loudly like a small explosion and can be heard across the whole house. Never had this before as the boiler was really quiet
Any suggestions

Jez
October 2012
Pilot flame either too low or too far away from main burner gas jets. Result is gas from main burner is not igniting as soon as it leaves the burner- instead it only ignites after sufficient gas has filled the burner chamber to propagate a flame from the pilot to the main burner gas. The result as you have found out is a mini explosion. In severe cases this will snuff out the pilot and you have to go through the the 'start up procedure, which is not helpful when you come home to a cold house and a 'locked out' boiler.
Possible faults:
a) Pilot regulator turned too low or dirt in needle valve strangling the flow of gas to pilot jet.
b)Main burner gas regulator not allowing sufficient gas to main burner.
c)Pilot assembly could be out of alignment.
note:- For a smooth ignition transmission the pilot flame and main burner flame should be touching.

Geoff in Wales
October 2012

Automatic Answer

We may have found other answers which could help you.

Click here for 80 Gas Boiler

Mend Heating, Home Heating Systems
Find out how to mend home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Find out how to mend home heating systems