Powermax 155x Backfires after running for 30-60mins?
I have had the boiler serviced and a part replaced. When the boiler is first switched on the usual ignition is fine but once it has run for 30-60mins and the ignition needs to kick back in, it Pops/Backfires. I take it as the Gas is running through and the Ignition has a delay and the chamber fills with Gas and when the element heats up the ignition has greater volume of Gas than required, hence the Pop/Backfire. What it the fault and what needs replacing?
Found the answer - The Ignition Element was worn and had a 10mm gap across the Sparking Point, instead of a 4mm Gap. Both ignition Element and the High Tension Lead replaced. Problem now fixed
Laz
January 2012