Recent: Trayford close coupled toilet?

Mend Vaillant Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Free repair help for Vaillant home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

Vaillant ecoTEC 828 pump starts with cold water tap?

When I turn on the cold water taps everything is fine until I turn the tap OFF. Then the pump (not the burner) on my Vaillant ecoTEC 828 starts and goes off after about 15 secs. If I flush the loo or use the cold water basin tap this does not occur - only applies to cold water taps in kitchen and on the bath. What could cause this ? The boiler has just beeen resited.

Tim Goadby
November 2011
Carefree - thank you very much indeed for your reply -its much appreciated and what you say makes perfect sense. I'm sure this will enable me to solve the problem.

Tim Goadby
November 2011
Most likely, a 'dead leg' in the hot/cold water system (a length of pipe running to a dead end), this will cause the aqua sensor to spin as the dead leg re-pressurizes after use thereby bring the pump in to life.
Find and cut off the dead leg, or alternatively, fit a non-return valve on the cold water inlet to the boiler.

Carefree
November 2011

Automatic Answer

We may have found other answers which could help you.

Click here for Pump Water Turn

Mend Heating, Home Heating Systems
Free repair help for Vaillant home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Free repair help for Vaillant home heating systems