Glow-worm ultimate 50ff ?

worked fine for 20 years, now keeps blowing 1amp fuse on pcb. is pcb at fault.....or could it be something else.

colin
January 2011
the fans are prone to sticking. try greasing/cleaning it. the extra power to start a sticking fan usually blows fuses on pcb

S.PRIESTLEY
January 2011
usually caused by a faulty solenoid on the gas valve

Gasman
January 2011

Automatic Answer

We may have found other answers which could help you.

Click here for Boiler Heating Fuse

Related Questions ...

Mend vaillant boiler fault f22
1

Vaillant condensing boiler ecoTEC plus?

The boiler stopped working and showed fault F22 dry fire. I changed the 3 amp fuse in the electric switch and ... [Read more]
Mend boiler temperature controller
4

danfoss SET3E contlolled heating system ?

In my Danfoss SET3E heating controlled system I can't turn the water heater section OFF! The switch on the... [Read more]
Mend central heating boiler pump
1

has the central heating pump gone no clock?

power to the spur dowmstairs keeps blowing the 3 amp fuse no clock or power to boiler in the kitchen has the p... [Read more]
Mend heating boiler valve
3

Glow-worm 30cxl?

Started off blowing 3amp fuse in boiler, water cold but heating working ok, engineer came out and fitted a ser... [Read more]
Mend boiler central heating programmer
2

Potterton Programmer not controlling stat?

I developed a fault on my Potterton system as a direct result of trying to change the in room stat (Potterton ... [Read more]
Mend timer stopped working
1

Randall 102 timer, my heating did not come on this morning please help?

My heating has suddenly stopped working. I have a back boiler system that has a Randall 102 timer on it. I rep... [Read more]
Mend boiler heating error codes
1

No power to my boiler ariston microgend 28?

Hi please help. I have had no water or heating since yesterday.Living in a rented house and cant get out the l... [Read more]
Mend saunier duval heating
1

i have saunier duval combi?

saunier duval combi boiler has no L.E.D display on boiler but fuse in plug ok ?what could it be? i have no hea... [Read more]
Mend heating hot water boiler
1

Alpha CB24 Flashing Indicator Neons, No Hot Water/Heating, please help?

On sunday I discovered my Alpha CB24 had no power. On inspection, the main terminal fuse had blown. With a bit... [Read more]
Mend boiler heating combi
1

my britony combi boiler has blown the internal fuses?

The boiler has blown the 3rd internal fuse when replaced blown again. no heating or hot water can it be fixed
Mend boiler heating potterton
1

Potterton 80e problems with reset switch?

LAst night when the heating was switched on, the boiler fired up and all was okay - suddenly there was fuse bl... [Read more]
Mend boiler heating engineer
1

how can i fix my boiler?

i have a 9mth old pro combi 100 he combination boiler and had an engineer out to fix it as the internal fuse b... [Read more]
Mend boiler thermostat heating
1

Baxi Solo 3 heats water but not CH?

My 5 year-old Baxi Solo 3 CH circuit has just packed up, although the water heating is fine. The CH is control... [Read more]
Mend boiler heating potterton
1

Potterton Netaheat 16-22 will not fire up?

My Dad has a Potterton Netaheat 16-22 MK 2 F boiler . it has not bean run for a few months(prior to this worki... [Read more]
Mend boiler programmer hot water
1

lp112 programmer is live and display works but is not giving an output to t?

Hi I have been asked to look at a domestic heating system, the boiler is Johnson stanley, the programmer is dr... [Read more]