Recent: Fix food processor motor?

Mend Ferroli Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Free repair help for Ferroli home heating systems

Mend > Home Heating Systems

Mend Ferroli Modena Pressure

Ferroli Modena 80E Losing pressure?

Hi, please can you advise? When the CH is used the pressure gradually reduces over a period of a couple of days, and then the system wont run. I have replaced the relief valve which was definitely faulty, and now the pressure holds up for much longer now - a couple of weeks. Is the expansion tank likely to be faulty? What pressure should it be charged to?

Norman John
July 2006
how do u set the pressure to 1 bar

LEE REILLY
November 2006
the exspansion vessel is usually charged to about 1bar.......... isolate flow and return valves on boiler drain through relief valve to take pressure off exspansion vessle when drained you can attach a foot pump with suitable gauge and re set pressure

baldy02920
October 2006

Automatic Answer

We may have found other answers which could help you.

Click here for Ferroli Modena Pressure

Mend Heating, Home Heating Systems
Free repair help for Ferroli home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Free repair help for Ferroli home heating systems