My beko condensor dryer has stopped heating. I have checked the elements and I am getting Cotinuity through them. Is there a reset button on them anywhere?
Regards
No resettable device. However a common problem is the main pcb . Check between grey and red wires on the connector on the pcb and if you get 240v then the pcb is broken.
billbo
January 2011
just fitted a start capasator on my beko drcs68w tumble dryer ,now its not heating up ,is there a reset switch of any kind
garethwoodward
December 2010
I'm using a set of stynal testers so I don't have a reading. What reading should I get? I do have a continuity tester to check it out. If there was a stat that needed resetting, I would expect to get an open circuit?
gary
October 2010
what readings are you geting through the stat and ntc sensor mounted on the side of the element?.One should be closed circuit and on will be a kohms reading
ck
October 2010
Automatic Answer
We may have found other answers which could help you.