Recent: Home max fs506x?

Mend > Home Heating Systems

Mend Vaillant GB242E Boiler Ignition Lockout

VUW GB242E no ignition?

The boiler goes through the lighting sequence on heating and water ,all lights on except burner then lock out . some times it will light and after will continue to light but it seems when it is cold it will struggle to light.
I have cleaned the fan venturi.
You hear the pump,fan and pressure switch click but no spark.

stevew
July 2010
cheers will check ,thanks

stevew
July 2010
Fan ventuuri? Blimey! Didn't even know there was one! (Which means you've shot off in the wrong direction).
You state the fan & pump are running, are the switches actually working?
Test the FPS electronically to make sure it it making, also check the pump switch (left of the pump just above) is the microswitch breaking when the pump runs?
1st check: FPS (If the fan is running)
2nd check: PPS (If the pump is running)
Otherwise, it's a pcb fault (relay)
On a 242e/1 it's the left hand pcb
On a 242e/2 it's both pcbs

Check in sequence to save spending unessecary money on pcbs

Carefree
July 2010

Automatic Answer

We may have found other answers which could help you.

Click here for Boiler Ignition Lockout

Related Questions ...

Mend worcester 28i combi
1

worcester 28i junior combi(no heat/water)?

Reset light flashing 4 times/sec and blue light flashes 1/sec. Think in ignition lockout as no flame.switched ... [Read more]
Mend boiler lockout pcb
1

worcester greenstar 30 si think its the pcb?

Can anyone shed any light. Gone to a customer boiler in lockout indicating ignition fault. Reset boiler pump c... [Read more]
Mend boiler heating lockout
1

Halstead Best 50 Boiler?

Ignition lockout light keeps coming on. Have replaced fan but problem is still there. This was reported by som... [Read more]
Mend combi boiler heating hot water
2

My Halstead combi boiler refuses to work any more - help please!!?

Hi, I have a 6yr old Halstead Ace High combi boiler which has never given me any problems until now. About 3 -... [Read more]
Mend 30 heating fault
1

Betacom 30 heating fault?

18 month old Betacom 30, hot water function works just fine. call for heat and problems start. Pump & fan run ... [Read more]
Mend ignition heating lockout
1

Halstead best 50 is it my aquastat or ignition control?

Boiler oka for 5 years had 4 services no probs. Then last year 1 or sometimes 2 ignition lock-out a month. for... [Read more]
Mend boiler ignition cold
2

Micron 60ff boiler. Ignition failure?

On most days, usually in the morning and evening when the boiler is programmed to come on from cold, this happ... [Read more]
Mend boiler ignition lockout
1

ignition lockout ariston micro genus 27 mffi gas boiler?

as soon as the boiler fires upthe ignition locks out hold the lockout button in it lights when it shuts down a... [Read more]
Mend boiler hot no ignition burner
1

No hot water?

halstead quatro boiler. The problem i have is no hot water. when i turn the hot water tap on the burner does ... [Read more]
Mend boiler pressure lockout
2

How to come out of lockout mode?

My worcestwer bosch 30 cdi boiler (Normal) is in the lockout mode. I have tried to take out any air. There w... [Read more]
Mend central heating boiler ignition
6

Central heating boiler ignition lockout?

I have an ongoing problem with my boiler, a Worcester Bosch 28Cdi. From time to time the central heating ligh... [Read more]
Mend fault overheat heating
1

How to fix and overheat fault on my Glow worm 15hxi {3yrs old}?

on sunday i had a fault 4 {ignition fault- lock out when lit}, then in the same afternoon it went to a fault 1... [Read more]
Mend baxi light lights
8

Baxi 100HE Ignition Lockout?

My boiler keeps getting the red fault light on permanently. The boiler lights OK but then shuts down after abo... [Read more]
Mend boiler heating circuit board
5

Halstead best 50 boiler cuts out?

I have a Halstead best 50 boiler. The ignition lockout keeps cutting the boiler out. I have had the circuit bo... [Read more]
Mend failing water combi
4

Failing hot water on a Saunier Duval F30E Themaclassic combi?

I have a 4 yr old Saunier F30E standard combi running on natural gas and the hot water is failing dismally. Ho... [Read more]

How to mend ...