how to refill central heating system?

I need to change a valve on a downstairs radiator, I have a Glow-worm Swiftflow Combi boiler. I have been told that I need a trained engineer to refill the system once the valve has been changed? As far as I can see, all I have to do is to refill using the filling loop and bleed all the radiators afterwards, making sure the correct pressure is showing on the gauge, and pouring in corosion inhibitor through the radiator....or is there more to it than this?

Ian
November 2004
ho do i find the refill loop on my glow worm swift flow 80????

emily
February 2009
to Ron Steenbergen. The filling tap on the cxi range with the blue extension are prone to snapping if over tightened.They are easy to replace but make sure you isolate the flow return hot and cold before removing the filling section which has metal retaining clips to hold it in place.Also prior to removal remove the pressure from the boiler by means of the black drain teat located under the boiler once isolated.

Darren Homar
October 2007
The presure in my glow-worm 30cxi is low and I am trying to fill it but I can't get any water in the system.
I tried the drain point and I tried the filling loop tap and extension tool, but both are not working.

please advice.

Ron Steenbergen
November 2006
Nope you've pretty much hit the nail on the head it is as simple as that just make sure the boiler is turned off while it is drained , ie so that the hot water part doesnt kick in , just turn off the mains power to it then do as you say and it should be between 1 to 1.5 bar when cold

steve
November 2004

Related Questions ...

Mend central heating diverter valve repair
1

Vaillant vcw gb242 eh central heating problem?

Hi just wondered if anybody can point me in the right direction, central heating wont come on, if you press th... [Read more]
Mend boiler diverter valve intermittent fault
1

Baxi Combi Instant HE80 boiler?

Intermittent fault on the hot water. Sometimes it comes on but when it doesn't I can sometimes get it on by tu... [Read more]
Mend central heating fault reset
1

Central heating not working?

My glow worm micron 50FF works for a short time then shuts down and both lights go out. Neither of the two lig... [Read more]
Mend boiler heating thermostat
1

combi oil Worcester greenstar heatslave 12/18 switches off?

I have a internal combi oil Worcester greenstar heatslave 12/18 Its has a built programmer and Hot water t... [Read more]
Mend timer central coming
1

When timer operating water heating the central heating is coming on aswell?

When my timer is operating the water heating the central heating is also switching on when not selected and by... [Read more]
Mend boiler central heating gas engineer
1

Diverter Valve bypass?

Hello, I have booked a gas engineer to come to fix my Mains Combi 24 boiler that appears to have a diverter... [Read more]
Mend warm radiators help
2

Luke warm radiators?

Really need help with a central heating problem (old, but sturdy back boiler open vented system in a flat - o... [Read more]
Mend boiler central heating grundfos
2

Heating?

I have an old Ideal W boiler (conventional) which heats the water cylinder and will go to central heating only... [Read more]
Mend temperature pressure sensor
3

Boiler Hot water intermittently losing temp, Heating seems fine?

The title explains the main issue, for some reason the hot water drops often every 20 secs or so, sometimes it... [Read more]
Mend boiler central heating ferroli
1

what is the part number for a central heating flow outlet valve on a ferrol?

What is the part number for a central heating flow outlet valve for a ferroli optima901 boiler
Mend central heating radiators temperature
1

potterton performa 30 HE?

Hi water working fine but when central heating is turned on upstairs radiators work ok but downstairs nothing.... [Read more]
Mend boiler pressure loss central heating
1

My Ariston Combi A boiler keeps losing pressure from Central heating loop?

Heating loop pressure drops to the red line twice a day. Cannot find any leaks from any of radiator and no lea... [Read more]
Mend pressure 24 combi boiler
2

Falling Pressure?

Each year at this time when I turn the heating on on my Linea 24 combi boiler after being off all summer, the ... [Read more]
Mend boiler central heating hot water
1

potterton ep2001?

'central heating' kicks in on all settings but the 'hot water' only settings fail to fire up boiler. Is it lik... [Read more]
Mend central heating out
5

Potterton perfoma30 HE Central Heating Cutting out?

New heat exchanger and divertor valve due to heat exchanger blocked. Now CH only cutting out, hot water is ok... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...