Recent: How to recoil the starter spring - Champion R484TR?

Mend Ferroli Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Mend repair fix Ferroli home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

ferroli optimax 25c?

no hot water turn on tap 3 way valve gos to heating and pump stops boiler gos off 03 fault .put 3 way valve to middle and lock remove power plug turn heating on works ok . turn hot tap on pump stops overheats burner gos out .turn tap off heating comes back on 2 to 3 mins later help not a bath for a week.

tony
April 2010
after 2 weeks of changing pumps 3way valves and temp sensors a man said it may be your pcb board but if you fit a new one you will have to change the parameter settings to match your boiler. so i rung ferroli support on 08715592927 to find out how to do it . after pressing reset and mode 2 or 3 times the boiler reset and has run ok .so i saved 160 quid on a pcb board and the boiler works fine thanks to ferroli support

tony
April 2010

Automatic Answer

We may have found other answers which could help you.

Click here for Ferroli Optimax 25c

Mend Heating, Home Heating Systems
Mend repair fix Ferroli home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Ferroli home heating systems