how do I stop a condensing boiler overflow from freezing?

British Gas installed a Worchester boiler for us nearly four years ago. The boiler has been working really well until the recent "cold snap". Now, however, the plastic overflow pipe (which is vented into an outside drain) is freezing up on a regular basis and preventing the boiler from working. I have been told that the best solution is to cut the pipe and drain into a bucket. It seems a bit extreme but I can see that it would work.Your comments would be appreciated.

Ray Govier
January 2010
Use electrical Isotape connected via a frost state

Stuart
January 2011
Our boiler overflow has frozen twice in a few days. The second time I tried the usual pouring warm water on the pipe and it didnt work. Phoned my plumber who told me that nearly every call he is getting was about condensing overflows freezing.
He suggested that I cut off the overflow pipe, did that and found the overflow pipe free of ice. Still the boiler did not work. The plumber suggested using a long screwdriver and probe the overflow pipe into the wall bingo I struck ice. The pipe was blocked nine inches into the wall. Used a hairdryer and the ice melted and we were soon able to restore the heating. My plumber is going to reroute the overflow pipe.

Barry
December 2010
The wire is called trace heating and works off a thermostat. The wire is cable tied to the pipe and then insulation put over the top of this. The thermostat is out side so when the temp drops to around 5 degrees the wire starts to heat reducing the risk of freezing!! Excellent bit of gear.

mouser
December 2010
british gas say they can fix a frozen vent pipe on my con boiler for £199 they will lag the pipe and put a wire thro it .understand the lagging but what,s the wire for

p.c
December 2010
Got the same problem in my overflow in the last cold snap, I have re-routed the overflow inside the loft with an exit out of the soffit which then goes straight down vertically to the guttering overflow pipe, I have used coiled plastic pipe so that there's no joints to drip inside and lagged it with one inch thick high density pipe lagging all the way from under the roof to the pipe. it has'nt frozen and this is on a north facing wall.

Andy
December 2010
We had our pipe cut and draining out freely - worked last year, but this year it is still freezing before it gets out of the cut bit of pipe - icicles coming out of the end of the pipe and pipe full of ice.

As our boiler is in the loft the pipe is high up so climbing on the roof with kettles of hot water not a realistic option.

Presumably some serious lagging is the answer but wonder why this wasn;t done as installation

VB
December 2010
I have also experienced the same problem with the condensation overflow pipe and BG came last Friday and cut my pipe. The engineer then poured a kettle of boiling water to unfreeze the rest of the remaining pipe. The boiler now works with the bit of the remaining pipe dribbling out onto the wall. The BG engineer said to call him back in a fortnight or after the current cold snap and he will come back and put the pipe (32mm diameter) back on.

What I think I would like to look for, is a permanent solution to stop the freezing occuring in the first place.

Jeremy
January 2010
you could up size the pipe, eg, from 3/4 inch to 1 1/4 or insulate the pipe with pipe lagging, hope this helps, also make sure there is a good fall from the boiler to the drain no dips in the pipe where water can collect,

hudds gas
January 2010

Related Questions ...

Mend gas 532i boiler
2

British Gas 532/i Gas Combi Boiler?

Hi Please could you help? I also have British Gas combi Condensing boiler RD532i. Installed 2006. Never given ... [Read more]
Mend boiler combi fault
1

Vaillant igniting issue ( domestic ) not CH?

Hello to everyone, I have a Vaillant sine 18 T-3 combi boiler that was installed in 1985. Have had parts repl... [Read more]
Mend boiler combi heating
1

Worcester 28i Junior Combi... Hot water but NO Heating ???

Hi everyone, We have a Worcester 28i Junior Combi which developed a fault this week. We have hot water fine b... [Read more]
Mend worcester 24 si ii
1

Worcester 24 si II?

Hi I have a Worcester 24si II. It's was installed 9 years ago. Had British gas around on monday for a new ins... [Read more]
Mend boiler combi condensing
3

Fault with BG Combi Condensing Boiler RD 532i - C1?

Hello out there..... Please could you help? I have British Gas combi Condensing boiler RD532i. Installed ... [Read more]
Mend boiler radiators hot water
3

Baxi back boiler , no hot water?

hi there, we have a Baxi back boiler and have recently had a new boiler tank installed by British Gas, but now... [Read more]
Mend thermostat heating wireless
1

Does anyone know how to reset the alarm on wireless thermostat receiver?

I desperately need help...3 years a go i had a new heating system installed with Britsih gas. Yesterday i ... [Read more]
Mend boiler heating system
7

I've had British Gas engineer out today - he's classified boiler as at risk?

Powermax HE boiler keeps cutting out - system apparently requires cleaning out but Gas Engineer doesn't say it... [Read more]
Mend condensing boiler hot water gas boiler
3

No Hot water from RD 532i Condensing boiler?

HI, We have no water at all from hot water tap (hot or cold) - cold water tap is fine. We`have a Gas condensi... [Read more]
Mend combi boiler thermostat heating
2

How can I make my combi boiler recognise the room thermostat ?

I have a combi worcester boiler installed by british gas. It has been fine until the batteries ran out in the ... [Read more]
Mend central heating boiler heating system
2

Yes I have the same problem, boiler doesn't turn off?

The central heating is on all the time, as the timer doesn't switch off the central heating. I got British Ga... [Read more]
Mend boiler radiators heating
2

Hot rads?

The c/heating boiler has just had it's annual inspection by British Gas and the engineer checked all rads and ... [Read more]
Mend boiler baxi fault
1

I have a Baxi Solo 2 PH60 boiler which has an intermittant start up problem?

My boiler was installed by British Gas in 1998. It has been fine but for the last couple of months it has deve... [Read more]
Mend problem combi installed
1

Can anyone give some good advice re this problem ?

We have a combi boiler installed in 1992 - Vallliant VCW GB Glowworm Spacesaver. It still works very well and... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...