Recent: Safely remove screen protector from a Macbook Air?

Mend > Home Heating Systems

Mend Baxi Bermuda 45/4M Heating Ignition Fault

my pilot light wont stay on its a baxi bermuda 45/4m?

It goes through the pilot igniting procedure ok but when I release the button after 30 seconds it just goes out?

Ally
June 2009
probably blocked pilot if pilot flame is not touching thermocouple tip, if it is touching thermocouple tip then new thermocouple required. get the appliance serviced by competent gas safe register engineer

t
June 2009
Ask your friendly gas man to call and fit a new thermocouple to your boiler. That'll sort it!

John
June 2009

Automatic Answer

We may have found other answers which could help you.

Click here for Heating Ignition Fault

Related Questions ...

Mend boiler ignition fault
1

Home heating systems?

I have a Glowworm 100f gas boiler system It has a fault where the ignition stays on when the pilot light is l... [Read more]
Mend boiler heating vaillant
2

Vaillant VCW, no hot water or heating! help desperatly needed?

I have a vailllant VCW GB 282E and the hot water and the heating do not work. I havnt had the boiler on for th... [Read more]
Mend 30 heating fault
1

Betacom 30 heating fault?

18 month old Betacom 30, hot water function works just fine. call for heat and problems start. Pump & fan run ... [Read more]
Mend Worcester Greenstar Fault
1

cannot get heating on?

have a worcester greenstar 24 i ignition light pressed reset but will not start up. wot can the fault be?? pl... [Read more]
Mend boiler combi heating
1

vokera linea 24 combi boiler problem?

when my boiler switches on to heat water in both heating and or domestic mode the green light changes to flash... [Read more]
Mend ravenheat csi 85 burner
2

Ravenheat CSI 85 A (T) Burner Cycling Constantly?

Hi all... I've got a Ravenheat CSI 85 A (T) combi and shows the following symptoms. It's fine with HW on... [Read more]
Mend ravenheat heating fault
1

ravenheat rsf100e no heating or hot water?

called to this boiler and found that it will go thro its start up procedure up to the point of pilot ignition ... [Read more]
Mend boiler heating fault
1

ICOS HE15- Boiler ignition banging?

Have Icos HE15 boiler. 2+ years old. Regularly serviced. Works OK on heating + hot water but has a problem wit... [Read more]
Mend combi boiler heating fault
2

Vokera HE Condensing Combi Boiler?

Got a relatively new vokera boiler - 18 months old and it has developed a problem over winter. Fault warning -... [Read more]
Mend boiler pcb ignition
1

Vaillant Turbomax constant ignition?

I have a Turbomax 242 with an intermittant fault which has now become permanent. when the boiler is switched i... [Read more]
Mend central heating seconds
2

My central heating does not work, it firesup then cuts out after 20 seconds?

I have a condensing fanned boiler the CSI 85T. The problem I have is with the central heating side in that whe... [Read more]
Mend combi boiler ignition intermittent
1

Valiant 828E Combi Hot water fault?

Hot water is intermittent, with ignition turning on and off (a real pain when showering). Heating is fine. Cou... [Read more]
Mend boiler fault ignition
4

does anyone know hy my vokera linea 24 cycles on and off?

my boiler lights the goes out every 5 or 6 seconds on heating and hot water flow and return clear pump running... [Read more]
Mend failing water combi
4

Failing hot water on a Saunier Duval F30E Themaclassic combi?

I have a 4 yr old Saunier F30E standard combi running on natural gas and the hot water is failing dismally. Ho... [Read more]
Mend boiler combi fault
3

baxi 105e just cuts out intermitantly?

i have a baxi 105e combi boiler. it cuts out with the flame failure light flashing .replaced both flame senso... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...