Recent: Fix food processor motor?

Mend Baxi Solo 3 Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Mend repair fix Baxi Solo 3 home heating systems

Mend > Home Heating Systems

Mend Baxi Solo 3 Fault Boiler Pressure

fault find baxi solo 3 pfl 60 boiler?

Only 106volts [not240v] at pressure switch, supply 240v to switch, fan will starts + ignition sparks but pilot will not light. I have fitted new circuit board + new potentiometer switch. Next constructive suggestion please.

Robin
October 2008
Why did you change PCB ?
Are you getting 106V between Live & Neutral or Live & Earth

a
October 2008
thanks for reply. Yes but again only 106volts

rupert1
October 2008
see if your getting power to gas valve

iain
October 2008
Mend Heating, Home Heating Systems
Mend repair fix Baxi Solo 3 home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Baxi Solo 3 home heating systems