Recent: Fix food processor motor?

Mend Baxi E168 Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Find out how to mend Baxi E168 home heating systems

Mend > Home Heating Systems

Mend Baxi E168 Boilers Boiler

What does error code E168 mean on baxi boilers?

I have abaxi Paltinum He33 boiler.
There is an error code of E168 in the display.
Can anybody tell me what this means?
Help!!!

Neil Owens
October 2008
We have had our Baxi boiler less than 12 months and have already had the engineers out twice. The first time was to do with the fan and the second was E158. A week later after having the 2nd fault fixed we now have error code E168 which is not in the manual. Thankfully we are still under warranty however it's a bit rediculous seen as we it hasn't been in a year yet. Baxi need to get their act together and sort it out because we are absolutely fed up with it. Hopefully we will find out what it is however the other answers on the website have helped.

Kate 'angry customer' Warrington - Cheshire
October 2012
Having just fixed one problem which caused an E168 I understand this a little better now. It seems E168 can indicate many different faults, all related to conditions which make it unsafe to operate the boiler. In my case it was a badly-fitted plug on the safety thermostat which had been removed by the service engineer in order to remove the expansion tank to repressurise it . I pulled it off, fitted it correctly and the condition cleared.

Trevor Daniels
March 2012
Knackered pcb, rubbish boilers anyway they either leak or just pack up completely. Get a glowworm or a woofter bosh!

Paul mcbernard
November 2011
earth problem. check all connections

pat
October 2011
If you've faced an E168 fault, either as an installer or a consumer, please sign the following petition. Please also pass on this petition link to anyone else you know that has suffered this problem. http://www.ipetitions.com/petition/e168error/

Stuart Wilson
April 2011
I've had them out 3 times all for this error and they seem totally at a loss as to why it keeps doing this. And so far they've replaced circuit board, cleaned the filters, changed the gas valve and it's still not working. I'm going to print out these answers and see if they can get it working! Landlords problem, but having to sit in and wait all day is a right pain.

Wend
April 2011
e110 is overheat cut out i think .........

me...
March 2011
133 is spark and ignition not 168....168 is a code for "boiler time out" which points to just about n e thing that isnt listed in the other codes. 8 times out of 10 it is the pcb....

me....
March 2011
what does E110 mean

jim
January 2011
After giving error code E133 several dozen times over 2 days & repeatedly being reset I too got error code E168 & it refused to be reset anymore... however, when the engineer came out he just removed a small metal 2 pronged pin adjusted the gap between the pins to 4mm, returned it to the boiler, & then left! Now the boiler is behaving nicely again.... Luckily my boiler is my landlord's problem but please note the machine can tell porkies which may cost you dearly if your repair man doesn't check this too!!!!

Relieved to have hot water!!!
July 2010
errore baxi 168 e dovuto al disturbo sulla linea di alimentazione 230v esempio variatori elettronici senza il filtro rc. errore provato e testato.ideale inserire un filtro rc su alimentazione caldaia.

claudio
April 2010
does code E168 come under a manufacturers fault? as my boiler is over 2 years old.

James
February 2010
E168 isnt in the manual error code list. It isnt available online either.

I was informed by the BAXI engineer its the PCB (circuit board). My 12 month new HE33 needed a new one, and twelve months to the day (today) it has gone again. I have one day left on my warranty.

Im not sure where they make these PCB's but Im not happy.

Regards

Gary 'PCB' Smith
November 2009
i had the same problem luck enough i still had baxi warranty they came along and replaced the electronic circuit board, worked like new

bobby
March 2009
boiler fault code E168 means igniter and spark generator faulty ie the generator isnt producing a strong enough spark therfore the boiler will try 3 more attempts then lock out a reset sometimes clears the fault temporarily

CHRIS
January 2009
I have just had the same problem. I phoned Baxi UK and they sent round a service guy. He advised that this is a software glitch. Apparently a load of boilers for the UK market were sent with Italian circuit board. This code mans something in Italy but not the UK. He has replaced the circuit board under warrantee.

Philip
October 2008
E168???? E160 is fan / fan wiring fault

iain
October 2008
Mend Heating, Home Heating Systems
Find out how to mend Baxi E168 home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Find out how to mend Baxi E168 home heating systems