Recent: Lg vcr?

Mend > Home Heating Systems

Mend Baxi Platinum He33 Boiler Error Code Heating

What does error code E168 mean on baxi boilers?

I have abaxi Paltinum He33 boiler.
There is an error code of E168 in the display.
Can anybody tell me what this means?
Help!!!

Neil Owens
October 2008
We have had our Baxi boiler less than 12 months and have already had the engineers out twice. The first time was to do with the fan and the second was E158. A week later after having the 2nd fault fixed we now have error code E168 which is not in the manual. Thankfully we are still under warranty however it's a bit rediculous seen as we it hasn't been in a year yet. Baxi need to get their act together and sort it out because we are absolutely fed up with it. Hopefully we will find out what it is however the other answers on the website have helped.

Kate 'angry customer' Warrington - Cheshire
October 2012
Having just fixed one problem which caused an E168 I understand this a little better now. It seems E168 can indicate many different faults, all related to conditions which make it unsafe to operate the boiler. In my case it was a badly-fitted plug on the safety thermostat which had been removed by the service engineer in order to remove the expansion tank to repressurise it . I pulled it off, fitted it correctly and the condition cleared.

Trevor Daniels
March 2012
Knackered pcb, rubbish boilers anyway they either leak or just pack up completely. Get a glowworm or a woofter bosh!

Paul mcbernard
November 2011
earth problem. check all connections

pat
October 2011
If you've faced an E168 fault, either as an installer or a consumer, please sign the following petition. Please also pass on this petition link to anyone else you know that has suffered this problem. http://www.ipetitions.com/petition/e168error/

Stuart Wilson
April 2011
I've had them out 3 times all for this error and they seem totally at a loss as to why it keeps doing this. And so far they've replaced circuit board, cleaned the filters, changed the gas valve and it's still not working. I'm going to print out these answers and see if they can get it working! Landlords problem, but having to sit in and wait all day is a right pain.

Wend
April 2011
e110 is overheat cut out i think .........

me...
March 2011
133 is spark and ignition not 168....168 is a code for "boiler time out" which points to just about n e thing that isnt listed in the other codes. 8 times out of 10 it is the pcb....

me....
March 2011
what does E110 mean

jim
January 2011
After giving error code E133 several dozen times over 2 days & repeatedly being reset I too got error code E168 & it refused to be reset anymore... however, when the engineer came out he just removed a small metal 2 pronged pin adjusted the gap between the pins to 4mm, returned it to the boiler, & then left! Now the boiler is behaving nicely again.... Luckily my boiler is my landlord's problem but please note the machine can tell porkies which may cost you dearly if your repair man doesn't check this too!!!!

Relieved to have hot water!!!
July 2010
errore baxi 168 e dovuto al disturbo sulla linea di alimentazione 230v esempio variatori elettronici senza il filtro rc. errore provato e testato.ideale inserire un filtro rc su alimentazione caldaia.

claudio
April 2010
does code E168 come under a manufacturers fault? as my boiler is over 2 years old.

James
February 2010
E168 isnt in the manual error code list. It isnt available online either.

I was informed by the BAXI engineer its the PCB (circuit board). My 12 month new HE33 needed a new one, and twelve months to the day (today) it has gone again. I have one day left on my warranty.

Im not sure where they make these PCB's but Im not happy.

Regards

Gary 'PCB' Smith
November 2009
i had the same problem luck enough i still had baxi warranty they came along and replaced the electronic circuit board, worked like new

bobby
March 2009
boiler fault code E168 means igniter and spark generator faulty ie the generator isnt producing a strong enough spark therfore the boiler will try 3 more attempts then lock out a reset sometimes clears the fault temporarily

CHRIS
January 2009
I have just had the same problem. I phoned Baxi UK and they sent round a service guy. He advised that this is a software glitch. Apparently a load of boilers for the UK market were sent with Italian circuit board. This code mans something in Italy but not the UK. He has replaced the circuit board under warrantee.

Philip
October 2008
E168???? E160 is fan / fan wiring fault

iain
October 2008

Related Questions ...

Mend boiler heating system error
1

Ariston Error Code E02 now A77?

Boiler loses pressure frequently, especially when cold, E02 code keeps coming up. After repressurising the boi... [Read more]
Mend boiler error code PCB
2

f7 error code-no heating/hot water?

Hope someone can help. My Worcester rd532i condensing boiler was working perfectly fine for year, then 1 day t... [Read more]
Mend boiler pressure fault
1

Vaillant Ecotech Plus 831 F22 fault?

I've been having problems for 3 weeks now, and on the 3rd plumber, and still not fixed. First had F75 fault a... [Read more]
Mend boiler heating error code
1

ferroli optimax HE31C the digital display is saying 'no CN''? ?

We have no hot water or central heating, no other error code is displayed. I've turned off at the mains, press... [Read more]
Mend central heating pcb
2

How can I fix my Ariston central heating boiler CLAS/ HE38?

Have replaced PCB in the boiler and "error code 302" has appeared it is communication error. Could it be one... [Read more]
Mend worcester greenstar error
1

Worcester combi greenstar intermittently not starting up/EA error code?

We have a 3yr old Worcester Greenstar combi boiler that is playing up. It has been intermittently not firing ... [Read more]
Mend How to mend it?
1

How do i solve a Remeha Avantaplus E7 fault code?

My boiler is approx 6yrs old and has now stopped supplying hot water after an E7 error code. The central heat... [Read more]
Mend boiler error code heating
2

what does the error code F1 mean?

My boiler is flashing an error code F1 and whilst it lights, it immediately goes out and I cannot get any hot ... [Read more]
Mend boiler pressure error code
1

Ferroli HE31C - Hot water but no heating?

There is an error code D2 on the boiler and no matter what I try I can't make it go away. I've tried turning i... [Read more]
Mend error code week
1

Ravenheat CSI 120 error code 04?

I have a Ravenheat CSI 120 on which I recently (last week) replaced the diaphragm in the diverter valve. I the... [Read more]
Mend boiler heating error code
1

british gas 532i flashing symbol?

I have found several items concerning this boiler but ours is not diplaying an error code but when the centra... [Read more]
Mend combi boiler central heating freezing
1

ea code?

Hi - looking after friend's house and central heating packed in. It's a Worcester combi boiler and EA message ... [Read more]
Mend vaillant boiler fault pressure
1

Vaillant ecotec 466 boiler f.75 5er code?

Hi we have the above boiler which has been displaying the F.75 fault code. We have had the pressure sensor cha... [Read more]
Mend boiler baxi radiators
1

how can i fix my boiler its a baxi megaflo 28?

i have a baxi megaflo 28 which will heat my hot water and downstairs radiators but when i select heating upsta... [Read more]
Mend boiler water pressure error code
1

fertech 31c boilder?

no hot water after installation of this boiler alongside a brand new central heating system? Error code F40 (... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.