Recent: Fix food processor motor?

Mend Glow-Worm Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Mend repair fix Glow-Worm home heating systems

Mend > Home Heating Systems

Mend Glow-Worm Flow 100 Pressure

Glow-worm Swift Flow 100 combi: pressure too high?

I just moved into a new apartment, and turned on boiler etc, then saw the pressure gauge indicates 3.2bar... I'm trying to find whether this is too high, as all comments I find seem to indicate something around 1-1.5 seems more normal. Landlord is not reachable and won't be for a few weeks, so I'm trying to figure out whether this is ok or I need to get an engineer asap.
Any ideas? Or where I could get the manual?
Thanks!

Jose
August 2008
pressure should be 1 to1.5 bar vent a radiator in a bucket to reduce pressure if pressure keeps increasing check filling loop is off or better still disconnected if pressure starts at 1/1.5 and rises you may have a burst expansion vessel or a blockage either case seek proffesional help

TOM WYLIE
August 2008

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Flow 100 Pressure

Mend Heating, Home Heating Systems
Mend repair fix Glow-Worm home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Glow-Worm home heating systems