Mend Baxi Bahama 100 Boiler Central Heating Radiators

Baxi Bahama 100 CH not working?

We have so far spent nearly £1000 over the last 2 years on our Baxi Bahama 100 boiler, the latest problem is that although we have HW the central heating does not work properly. The system has been power flushed but the water is piping hot and the rads are too when we first put the CH on even though the TRV'S are on a low setting. The water pressure rises into the red and the system cuts out. Any suggestions as to what the problem is?

damsel in distress
September 2005
Check the air pressure in the pressure vessel with a car type pressure gauge. Should be 5 psi at least. Any water that might come out of the valve means you have a leaky diaphragm in the unit and it will need to be replaced. Look underneath the unit for blemishes in the red paint. (That would suggest a pin hole). If air is leaking out you should be able to feel it or hear it. Please note pressure on the fixed gauge on the system DOES NOT mean there is air pressure in the vessel. It's a bit like a leak in a bike tyre.....

Silver Surfer
May 2010
pressure vessel pressure vessel pressure vessel

the boiler man
February 2007
the pressure keeps fall on the boiler. i keep having to top it up to 3 then a month later its back down to the red. does anyone know the problem and the price i should pay to repair it.

noel
December 2006
sounds like you have left the fillling loop on which is quite dangerous.dont wanna leak now.make sure the setting is on 1.5 bar by turning off the taps for the filling loop minside the boiler and releasing some water to drop the pressure.

simon
September 2005
Your expansion vessle has lost the air inside it. You can re pressurise it using a car foot pump. You will also notice water dripping out of the 'blow off ' pipe. the pressure should be around 0.6 bar. I have noticed that if your boiler has gone into the red it seems to loose it's air (check the valve as you did as a kid (spit on the valve and look fore the bubbles if it does then replace the internal valve.

Gary
September 2005
sounds like a pump need renewing

ex bAXI ENG
September 2005

Related Questions ...

Mend working firing hot
1

My central heating is not working?

My Valient turbo max plus 824e is not firing up for heating radiators. Hot water is o.k. The room thermostat c... [Read more]
Mend boiler central heating diverter valve
4

Baxi 105e?

I have a Baxi 105e boiler, it has started to heat the radiators when the hot water tap is run. I've replaced t... [Read more]
Mend combi boiler central heating radiators
1

why is my combi boiler not staying fired for central heating. water fine?

my Glow worm combi has been having odd days when the central heating isn't working but then has been ok again ... [Read more]
Mend boiler heating thermostat
1

combi oil Worcester greenstar heatslave 12/18 switches off?

I have a internal combi oil Worcester greenstar heatslave 12/18 Its has a built programmer and Hot water t... [Read more]
Mend central heating Worcester Bosch thermostat
2

My heating is on?

Thermostat is turned off so the central heating shouldn't be on. However the radiators are all giving out heat... [Read more]
Mend boiler fault code heating
2

What can I do about a Glow-worm Flexicom 30cx fault code F11?

I had a new boiler fitted in April this year. Last eve it stopped working, showing f 11. We have not been us... [Read more]
Mend boiler central heating radiators
1

is a brittany 2 a central heating boiler?

Does a BRITTANY 2 Boiler heat radiators
Mend warm radiators help
2

Luke warm radiators?

Really need help with a central heating problem (old, but sturdy back boiler open vented system in a flat - o... [Read more]
Mend thermostat wireless heating
1

How do I reset my wireless Siemens RDJ10RF thermostat?

"I have a wirelss Siemens RDJ10RF thrmostat with RCR10/433 receiver.""The lights on the receiver have gone out... [Read more]
Mend combi boiler central heating fault
1

240 combi boiler reduce hot water temperature?

The temperature of the hot water is reduced from normal although the central heating radiators are fine has an... [Read more]
Mend boiler leak heating system
1

Radiator problem ?

after a recent leak in my central heating system which is now fixed, i've refilled the radiators and fired the... [Read more]
Mend central heating boiler ignition
1

Ideal classic central heating boiler?

Ca anyone help please. My boiler omes o and then after a out hAlf an hour it cuts out.when it tries to igni... [Read more]
Mend central heating radiators temperature
1

potterton performa 30 HE?

Hi water working fine but when central heating is turned on upstairs radiators work ok but downstairs nothing.... [Read more]
Mend central heating radiators hot water
1

heat water up in boiler keep flowing into radiators?

potterton suprima. put central heating on to heat up water in tank but in less than half an hour hot water s... [Read more]
Mend rid air system
2

How can I get rid of trapped air in central heating system?

After replacing the small rubber seal on the shaft of the hydraulic actuator in my BIASI 24S Combi boiler, the... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...