Recent: Fix food processor motor?

Mend Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Mend repair fix home heating systems

Mend > Home Heating Systems

Mend System Replaced Boiler

Glowworm Ultimate?

Changed a radiator to my system so drained down and replaced, when I filled the system back up and fired the boiler all ok. A few minutes later the boiler tripped off we reset and this happened 5/6 times. We realised the water pump had locked and the boiler was over heating so we freed up the pump and the boiler worked again but now the boiler is tripping off and we have to reset it. The water pump is working so I am wondering do you think the thermostat is knackered on the boiler?

Mark
February 2008
Hi, have you managed to find a solution to your problem? I drained my system last night and now it won't work!!

I don't have a header tank in the loft but the cylinder in the airing cupboard does have a little tank at the top which is full.

To drain the system, i turned off the mains to the house.. drained everything, turned the mains back on and i've no water in the radiators. Bled them this morning and 3 of radiators are now full of water but the rest don't have air or water coming out of them.

When i turn the Heating on.. it fires up fine, the pump starts going and after about 30 seconds, the boiler has a fit and shuts off then the pump starts making funny noises.

I've turned everything off and unplugged the pump to stop it dying.. i keep bleeding the radiators but nothing is coming out yet (apart from the 3 with water in them).. anyone got any idea's? It's an old system.. a glow worm ultimate boiler and no pressure guages so i assume it's not pressurised.

Mark
February 2008
I was told this by a mate of mine but all rads are getting hot plus I have bled all rads and no air is coming out. I also tried to crack open a joint on the cylinder but didnt get any air out.

Mark
February 2008
your system is airlocked so the hot water from the boiler isnt circulating and the boiler stat is reaching temp and cutting the boiler out. if you want to verify this, next time the boiler cuts out, feel the pipes above the boiler and one will be too hot to touch. if was working b4 u drained it down its unlikely that a component is broken.

carl
February 2008
Mend Heating, Home Heating Systems
Mend repair fix home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix home heating systems