AC Motor Type 904/1158/07 RPM 800/1500
how to dismatel for inspection,arcing occurring inside windings after an earthing wire broke, i beleive it caused short as motor does not power up but is free to turn by hand with power disconected
hi all you have to manually turn programer round is it worth having it fixed
jayjay21up
December 2010
motor stopped working, fault traced to dirty commutator points/worn graphite brushes. I dismantled the casing before realising that the brush assembly is easily removed by levering the plastic holder, but watch for the springs/brushes ! hey presto, once all reassembled, it works.
alan
April 2009
the same problem i have
carbunii sint d vina ...
udne gasim carbuni pt acest tip d motor ???
johny
March 2009
theres no power
sean
March 2009
this is the 800 - door not opening
j
October 2006
you just need to remove the nuts and bolts you can't get the front off as it is welded check the thermal trip in the windings just follow the wires