Recent: Replacing full bulb housing unit in Neff oven?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Boiler Going Pilot Light Burner

Free repair help

We have 136 questions about mending 'boiler going pilot light burner'

How to mend ... Boiler Going Pilot Light Burner

Pages 76543
Mend Heating, Home Heating Systems

Potterton Prime F 30 - Main Burner Problem ?

Hi I am currently experiencing an issue with my boiler,when boiler is switched on the pilot light comes on an... [Read more]
Mend Heating, Home Heating Systems

how can I tell if the gas valve is being switched?

We have an old Potterton Netaheat 5/10 boiler, everything seems to be working, except gas to the main burner! ... [Read more]
Mend Heating, Home Heating Systems

Baxi Solo 2PF 40 ?

Problems with boiler pilot not working burner light not on new fan working nothing happening whats wrong pleas... [Read more]
Mend Heating, Home Heating Systems

how can i fix my potterton netaheat 10/16 boiler electronic?

my boiler wont light up, the fan comes on and then it should ignite pilot and then burner but it does not go t... [Read more]
Mend Heating, Home Heating Systems

glowworm space saver 50 bf?

help my boiler is firing up for about 1 minute then cuts off the pilot light i have changed the thermocouple t... [Read more]
Mend Heating, Home Heating Systems

no hot water ?

pilot was on. turned on tap no main burner maybe air pressure switch as number 7 led is not on.now i have no p... [Read more]
Mend Heating, Home Heating Systems

Glowworm 67 boiler pilot light?

I have fitted a new thermocouple and the pilot light stays on - BUT - when the main burner come on it closes d... [Read more]
Mend Heating, Home Heating Systems

how to get pilot and burner on. Baxi solo?

I have just fit a new air pressure switch. The boiler light is on and the fan is running but the pilot and bur... [Read more]
Mend Heating, Home Heating Systems

No green burner indicator on ?

Hello, I have a Worcester Greenstar Ri. Last few days have had the heating off and only hot water on. Last nig... [Read more]
Mend Heating, Home Heating Systems

main burner on apollo 65/50 b won't ignite?

can anyone help...a new thermocouple and cap have recently been replaced in the apollo 65/50b boiler we have. ... [Read more]
Mend Heating, Home Heating Systems

Boiler does not fire up?

The pilot light is on, the pump is working, the fan at the top of the boiler is working but when turned on it ... [Read more]
Mend Heating, Home Heating Systems

Marathon 600b floor mounted boiler wont stay lit!?

When I light the pilot light there is no problem, remains lit many hours later! When I switch to continuous or... [Read more]
Mend Heating, Home Heating Systems

can i buy a neta heat 10-16 mk2f gas valve?

i have a neta heat 10-16 mk2f boiler and only from yesterday the pilot light ignites but the main burner doesn... [Read more]
Mend Heating, Home Heating Systems

Got A Baxi Solo 3 60 f?

The Boiler and fan light comes on but no pilot light or burner light has anyone got any idea what could cause ... [Read more]
Mend Heating, Home Heating Systems

potterton netaheat 12-16 mk2?

pilot light clicks on(i can see it has lit) then i wait for the main burner to come on but it doesnt always co... [Read more]
Mend Heating, Home Heating Systems

Glow worm Space Saver 50 MK11 fault?

Please can anyone help? Boiler keeps tripping out. Pilot light stays on fine. When you turn the 'min-max' swit... [Read more]
Mend Heating, Home Heating Systems

Potterton Prima 40 B fault?

hello, can anyone help? Our gas boiler has developed a fault( christmas eve) pilot light all okay but boiler w... [Read more]
Mend Heating, Oil Filled Radiators

no heat in rads?

i have a baxi gas boiler 2pf. pilot, fan, boiler and burner lights on. overheat light not on. doesnt heat rads... [Read more]
Mend Heating, Home Heating Systems

how do i convert my electronic igniton boiler to free standing pilot?

how do i convert my electronic igniton boiler to free standing pilot on my saunier duval water heater 2001 mod... [Read more]
Mend Heating, Home Heating Systems

What could be the problem if boiler fails to fire up?

main burner does not ignite, boiler fails to fire up, pilot light ok, pump ok, room stat ok. programmer ok.No ... [Read more]