3 hours ago: Will I need to replace my garden tap?

Mend > Home Heating Systems

Mend Potterton Profile 60e Boiler Heating Electrode

Potterton Profile 60e Boiler Pilot Light?

Is this boiler supposed to have a pilot light and if it does should the flame enclose the electrode when lit. On my boiler the pilot flame is very small (within shroud) and only encloses the electrode when it fires up.

Geo
August 2007
This type of boiler does have a pilot but it isn't permanant like the old type. The only time the pilot lights is when you want the boiler to fire up. This is called electronic ignition, hence the e at the end of profile 60e. And yes, it is meant to be small and be in contact with the electrode as this both lights and senses the flame.

Neil (Baxi engineer)
August 2007
This type of boiler does have a pilot but it isn't permanant like the old type. The only time the pilot lights is when you want the boiler to fire up. This is called electronic ignition, hence the e at the end of profile 60e

Neil (Baxi engineer)
August 2007

Automatic Answer

We may have found other answers which could help you.

Click here for Boiler Heating Electrode

Related Questions ...

Mend boiler error code PCB
2

f7 error code-no heating/hot water?

Hope someone can help. My Worcester rd532i condensing boiler was working perfectly fine for year, then 1 day t... [Read more]
Mend ravenheat pcb central heating
1

my ravenheat rsf 84 et boiler?

can someone help me my reavenheat rsf 84 et boiler when you turn on the hot water the boiler fires up ok then ... [Read more]
Mend combi boiler boiler repair no heating
2

how do I fix my combi boiler, SIME FORMAT 80E?

I guys, never used this site before, though I give it a go. Woke up this morning no hot water and no heating.... [Read more]
Mend boiler fault electrode
1

vaillant turbomax vuw 242e?

HELP!!! I have a vaillant turbomax boiler that goes throughthe light-up sequence, to the stage where the pilot... [Read more]
Mend boiler heating fault
1

worcester 350 combi 10 years old two pumps?

the pilot lights but the flame doesn't spread across the burner to the flame sense electrode this happens on b... [Read more]
Mend 30 heating fault
1

Betacom 30 heating fault?

18 month old Betacom 30, hot water function works just fine. call for heat and problems start. Pump & fan run ... [Read more]
Mend boiler bosch 24i
1

Loud buzzing noise when boiler ignites?

I have a Worcester Bosch 24i RSF boiler and it is making a very, very loud buzzing (kind of electrical) noise ... [Read more]
Mend boiler heating relay
1

Potterton Promax 15HE Boiler -relay clicking problem?

Hi, Need some help please. A 6yr old Potterton Promax 15HE on an unvented boiler installation has suddenly st... [Read more]
Mend heating temperature overheat
4

Worcester 19/24CBI Problems (Over Heating, Fail to ingite)?

Hoping that someone can shed a little light on my problem or that this may help someone in a similar position.... [Read more]
Mend boiler heating Worcester
2

Chaffotaux Mauray britony boiler?

The boiler started making a click, click, clicking noise before it broke down. 14/12/09. It still fires up but... [Read more]
Mend boiler gas heating
2

Urgent advice needed as my Gas boiler has a mind of its own!?

Iv moved into a huge Georgian town house apartment which houses an old; Potterton Kingfisher MF CF60 Boiler... [Read more]
Mend boiler central heating gas valve
1

Heatline C24 not firing up!?

Can anyone help please... I have a Heatline C24 boiler which is now just over 3years old. It has started pl... [Read more]
Mend boiler electrode pilot light
3

My Glow-Worm Ultimate 70FF won't light?

The boiler fails to light, with no spark at the electrode. The pump turns on and off under control of the room... [Read more]
Mend boiler fault heating
1

NO PILOT LIGHT ON GLOW WORM ELITE 21 PLUS BOILER?

THE BOILER IS BY GLOW WORM , THE MODEL IS ELITE 21 PLUS (SERIAL NUMBER (01013677) I CHANGED PILOT INJECTOR AND... [Read more]
Mend boiler fault ignition
4

does anyone know hy my vokera linea 24 cycles on and off?

my boiler lights the goes out every 5 or 6 seconds on heating and hot water flow and return clear pump running... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...