disconnect power
1) unscrew two screws at the back just below top panel.
2)slide off top panel
3)unscrew two screws at top of the front panel
4)pull out soap dispenser (no screws)
5)unscrew two screws behind soap dispenser
6) front panel comes loose, unclip from inside at the right hand side of the machine
7) unscrew two top screws at top panel
8)disconnect pipe at back and tip machine on it's back.
9)open bottom filter compartment and unscrew three screws, panel lifts off.
10) unscrew bottom two screws of front panel. The front panel is still connected to the drum, but it will now come off sufficient to access the pumps.
good luck
Filip