Recent: Safely remove screen protector from a Macbook Air?

Mend > Home Heating Systems

Mend Ariston Microgenus Gas Boiler Heating Error Code

how can i fix my Ariston Microgenus gas boiler?

when i switch the boiler on; the fan comes on but does not light up. e34 shows up.

paul
July 2007
The air pressure switch is not closing

could be
low pressure differential between flue inlet and outlet caused by

leak in the tubing or tube/fan connection
leaking fan seal or not seated properly
Dirty fan
blockage in the flue inlet or outlet

OR defective pressure switch (diaphragm or switch)

andy
July 2009
e34 represents an air pressure switch problem...I suggest checking the aps tube from aps to fan for a blockage....probably blocked with water

IAN DITCHBURN
July 2007

Automatic Answer

We may have found other answers which could help you.

Click here for Gas Boiler Heating Error Code

Related Questions ...

Mend boiler error code PCB
2

f7 error code-no heating/hot water?

Hope someone can help. My Worcester rd532i condensing boiler was working perfectly fine for year, then 1 day t... [Read more]
Mend boiler heating error code
1

ferroli optimax HE31C the digital display is saying 'no CN''? ?

We have no hot water or central heating, no other error code is displayed. I've turned off at the mains, press... [Read more]
Mend worcester greenstar error
1

Worcester combi greenstar intermittently not starting up/EA error code?

We have a 3yr old Worcester Greenstar combi boiler that is playing up. It has been intermittently not firing ... [Read more]
Mend central heating error code boiler
1

british gas 532i flashing symbol?

I have found several items concerning this boiler but ours is not diplaying an error code but when the centra... [Read more]
Mend boiler heating error
1

A01 error on boiler Ferrolli Optimax?

I have a new Ferrolli Optimax boiler. I keep getting A01 error code on my boiler and cuts out all heating and ... [Read more]
Mend heating pressure error code
2

BG 532 have hot water but no heating?

I have a British Gas 532/i boiler which is approx 3 years old now with a WR1 wireless receiver and a RC5 trans... [Read more]
Mend boiler error code ignition
3

Ravenheat error code 01?

Hello, My ravenheat boiler is coming up with 01 on the display and when this code comes up, no hot water or he... [Read more]
Mend baxi error combi
1

baxi duo tec combi e133 error code?

Gas Networks have recently replaced all the gas pipe in our road which made it necessary for them to turn off ... [Read more]
Mend pressure heating turned
1

valient eco pro pressure gauge?

The pressure is in the red when the heating is on, when it is turned off it loweres, can i lower this myself, ... [Read more]
Mend combi boiler supply
1

E133 error code?

Hi I have a combi boiler Promax Combi HE Plus A, i keep getting error code E133 which is a gas supply fault... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.