Recent: LG FC930W Safe Mode: Unlock Front Buttons Without Remote

Mend > Home Heating Systems

Mend Glow-worm Ultimate 40FF Boiler Ignition Glowworm

glowworm ultimate 40ff?

i put the boiler on and the pilot lights but the main gas burner wont light up,the ignition just keeps sparking,i have replaced the pcb but it is still happening.

v reed
June 2007
I had this same problem, eventually found that it was sparking on the case as mentioned. I used insulating tape like others, but will now look at replacing with a more sturdy fix. Thanks

MJD1066
November 2008
Got the same problem with my ultimate, its sparking but not firing up, I have looked and realised that its actualy sparking onto the casing and the wire is slightlty charred, insualting tape works for a while but a new lead is required.

Tony m
January 2008
A common problem on the ultimate is the ignition lead shorting out on the casing where it enters the combustion chamber, I find that insulating the lead with silicone tubing cures this problem.
I have found them insulated with electrical tape, this works fine for a while but the heat causes it to break down.

gary.wright53@googlemail.com
July 2007
it is either a choked pilot or the electrode is faulty the message is not getting back to the pcb to go to the second stage this is a job for a competent corgi registered engineer

ricky
July 2007
If you do find out, please let me know!

Andy
June 2007

Related Questions ...

Mend boiler ignition fault
1

Home heating systems?

I have a Glowworm 100f gas boiler system It has a fault where the ignition stays on when the pilot light is l... [Read more]
Mend heating boiler glowworm
1

Ignition lock?

Control panel on my micron glowworm boiler model 50 FF showing ignition lock... so any one advise me what I c... [Read more]
Mend fault overheat heating
1

How to fix and overheat fault on my Glow worm 15hxi {3yrs old}?

on sunday i had a fault 4 {ignition fault- lock out when lit}, then in the same afternoon it went to a fault 1... [Read more]
Mend pilot light appreciated
1

pilot light wont relight on my boiler..any help will be appreciated??

my pilot light recently stopped working on my glowworm economyplus 80(443267) boiler and it is electric igniti... [Read more]
Mend boiler glowworm ignition
4

Glow worm fuel saver f not working?

Came down stairs this am and found boiler not working. Timer ok but boiler dead, no fan noise, no ignition, no... [Read more]
Mend heating ignition gas
2

glowworm boiler not firing up?

I have a glowworm boiler and went to turn it on the other day to find it wouldnt light. Pilot light has gone o... [Read more]
Mend heating flame pump
3

Boiler does not ignite. Glowworm compact electronic?

The lights are on except for the flame light when demand is called for, but when demand is called for the boil... [Read more]
Mend heating thermostat glowworm
3

Glow worm Fuelsaver F - switches off!?

Having had the heating off all summer, I turned it on for the first time yesterday, everything worked fine the... [Read more]

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Home Heating Systems ...