I answered the same question some time back [Holland ring a bell?]
Follow Johnny's advice and re-route the waste.
Or an alternative method insert an Air admittance valve in the shower waste pipe on the run between the shower and toilet waste pipe, then the water should not be sucked out of the shower seal trap when the wc is flushed.
Go to www.wavin.co.uk this is the Osma pipe & fittings website. Select 'Technical tool box' on the top status line
then select the following in the order you see them 'Installation guide', 'Above ground drainage'
'Waste & Traps' 'Osma push fit waste Installation guide'
' Osma Vent 40 Air admittance valve'. Read the top of the page then scan down to see the drawings. the part number in my book is 4S.303 pge 30 of the Wavin/ Osma trade booklet
price £26.69. but expect more as that's trade.
you can also e-mail them info@wavin.co.uk they may well come up with another cheaper idea.
bob
bob
February 2005