Potterton perfoma30 HE Central Heating Cutting out?

New heat exchanger and divertor valve due to heat exchanger blocked.
Now CH only cutting out, hot water is ok.
Heating comes on for a minute and cuts out and starts modulating. Starts again for 30 seconds and cuts out, repeating.
Flow luke warm and rads cold whilst pump is hot .

Tony
October 2013
Kash. Worked ok for a couple of hrs after fiddling eith pump and divertor valve. Problem again

Tony
October 2013
Kash. Checked pump, Spinning ok and ruuning also.
The divertor valve plunger is ok also. The divertor valve cold also.
Could it be sludge blocking CH system that all pipes are cold.

tony
October 2013
poor flow. either blockage as mentioned before or diverter is not letting water through sufficiently. after u removed the screw fro the front of the pump can u hear or see the bit inside spinning. if its spinning then its the above mentioned problems. if pumps is not spinning try rotating the head inside with either a screwdriver or alan key.

kash
October 2013
A1 full of pressure and no air as bleeding done. CH Pipes flow luke warm whilst pump hot.

tony
October 2013
I assume you filled the the heating system and pressurised it then bled it etc

A1
October 2013
Mend Heating, Home Heating Systems