Mend Vaillant 828e T/max Boiler Heating System Thermistor

Dhw only Luke warm?

Hi ,I have a vaillant 828e T/max dhw is Luke warm at its very best, I have replaced thermistor 1,cleaned plate heater .The diverter valve is working fine as is the heating side the boiler is 12 years old,can anybody advise.

Amrick
February 2013
Hi Kash bought new plate exchange about 50 quid from eBay works a treat,thanks for your help

Amrick
February 2013
i thought so. u cant flush it with water u need to clean it properly by dissolving the iron oxide inside the heat excahnger. to do this go to the plumbing merchants or ebay and buy senteniel x800 jetflo cleaner. now boil a kettle of water and find a small bucket. fill the bucket with the x800 cleaner tub. then add the kettle of boiling water. then put on rubber gloves and put the heat exchanger in the bucket. leave it in there for two minutes. then while its in there after two minutes shake it around turning upside down. then remove it upwards so the water drains back into the bucket keep doing this for around 10mins then just wash it out with clean water and refit the heat exchanger to the boiler. if the heat exchanger is to badly blocked then u will require a new one on ebay u can now get chinese copies of them that are just as good as vaillants for half the price

kash
February 2013
Hi Kash I flushed it out under running tap water and blew Thur it ,water was free flowing and no debri came out,what I have notice the two pipes which feed the plate heater via the heat exchanger are very hot to the touch the dhw coming out of the plate heater is only Luke warm

Amrick
February 2013
how did u clean plate exchanger

kash
February 2013

Related Questions ...

Mend boiler gas pressure temperature
1

where can i measure gas pressure on a worcester 230 boiler?

where do you measure the gas pressure on a worcester 230 boiler, my boiler will not turn off when it gets up t... [Read more]
Mend combi boiler heating thermostat
4

RAVENHEAT ls100t - warm water only, heating ok?

Hello, I'm hoping someone may be able to help. My combi boiler was fitted around 6 years ago, and after two ... [Read more]
Mend boiler heating relay
1

Potterton Promax 15HE Boiler -relay clicking problem?

Hi, Need some help please. A 6yr old Potterton Promax 15HE on an unvented boiler installation has suddenly st... [Read more]
Mend boiler heating thermostat
2

cannot adjust temp on heating on vokera excell 80 sp?

i usually leave my heating on half way on the tempurature dial, but the radiators are boiling hot so it seems ... [Read more]
Mend heating system temperature diverter valve
3

Hot water prob - Vaillant Turbomax Plus?

For about the last 6 weeks or so our hot water temp has been very unstable. The boiler fires and heats wat... [Read more]
Mend boiler pcb thermistor
3

How can i fixMy Glowworm Micron 70FF?

My 70ff Boiler has had difficulty igniting. I would find that the fan was running but the boiler/rads were col... [Read more]
Mend boiler fault heating system burner pressure
4

vokera options boiler fault ,please help?

my vokera options boiler cuts out after 10-15 seconds ,the flow pipe at the boiler gets very warm but rads not... [Read more]