Have tried everything in manual under trouble shooting. Alarm will not set have done all the walk test, strode test etc. But when we try to set it always highlights zone 3 and beeps 9 times. We have link tested the detector in zone 3 and does not appear to be a fault with the detector as prolem was not solved. Have tried programming to omit zone three and when we try to set it still lights zone three up on control panel and beeps 9 times. Have stretched spring on tamper button but still can not set - anyone have any idea's?? thanks
not rocket science acorn,as you know,anyway acorn,happy new year when it comes.
gts
December 2011
Sorry,
I'm miles away to day, too much XMAS.
Take out >
"indicated as being on ZONE 3" < This panel does not indicate the location of the tamper problem.
acorn
December 2011
DUH.
The manual tells you that beeping 9 times is a TAMPER FAULT, indicated as being on ZONE 3.
acorn
December 2011
Automatic Answer
We may have found other answers which could help you.