can i use 2.5 swa cable to power my shed? im going to spur off my house ring ring with a 13 amp switched spur. i have been told to fit an rcd unit in my shed which will protect the wiring. i want two strip lights and two sockets. also my house has just recently been rewired with a 17th addition db. is this the correct procedure or do i need a second opinion?

sarah123
September 2011
that sounds ok - as long as the distance isnt too far (i wouldnt go more than 20mtrs on 2.5mm) - if its further install 4 mm armoured instead.

Remember that your avalible supply in the shed will be 13amp in total - so if you have any fixed aplliances make sure they will not exceed this

ray d
November 2011
What you are doing is ok but if your house sockets are protected by an RCD you dont need to fit another one