Mend Veritas R8 Alarm

how can i fix my veritas r8 alarm?

since decorating when i moved 2 sensors my system will not set (all 6 zone leds are on), none of the sensors are detecting movement. Does the system need to be reset?

phil
May 2011
thanks for the advice I checked the glass fuses and found the one labelled "speaker" had blown. the alarm is as good as new. I couldn't see one labelled "aux" but the alarm is over 10 years old so I guess the newer ones may be different.

phil
May 2011
when you have the pirs open,try testing if you have any power at them,before you start opening the control panel,

gts
May 2011
Try opening the detector and making sure the wires have not come out of the unit (PIR). if they have connect them back up. Go to the panel and with a mulit meter test the glass fuses. The Auxillary fuse will be blown

Mark
May 2011
Sounds like you have blown the aux fuse its located in the control panel. Beware live mains voltage is present inside the panel and if you are unsure call out a pro

TomTv
May 2011
Mend Security Systems, Home Alarm Systems
Free repair help for Veritas R8 home alarm systems