Mend Baxi Solo 2 50 pf Thermostat Pcb

Baxi Solo 2 50 pf?

wont work any body help please.
Problems are as follows
overheat light on and wont go out I have changed the over heat thermostat and the thermostat and replaced the main PCB.The pump is running all the time the power is on and the fan does not run, There are no volts from the PCB to the fan.

Gary
July 2010
Some more info if its of any help,When the power is on the overheat light comes on,When i turn the heating or water on the boiler light comes on as well with or without the temp control on or off.

Gary
July 2010
Hi Ian i have checked the continuity of both stats and both are ok ,Any thing else you can think of ?
The overheat light come on as soon as the main power is turned on even with the temp control off.

Gary
July 2010
check the wiring harness to the overheat stat for continuity.

Ian
July 2010

Related Questions ...

Mend boiler heating faults
1

My Baxi 105 is showing no faults but will not start up?

Electricity at our home was off for over 12 hours. Wewere told that if we plugged out generator into a socket ... [Read more]
Mend thermostat heating boiler
1

How can I make my Baxi Solo 3pf 80 cycle shorter?

My boiler is suffering from an extremely long cycle (20 min. on / 60 min. off). The thermistor cuts out at 80Â... [Read more]
Mend baxi solo 3 pf 60
2

My Baxi Solo 3 pf 60 keeps overheating?

I have replaced the thermostat sensor but to no avail. My plumber reckons the PCB may be at fault. British Gas... [Read more]
Mend boiler combi fault
9

Baxi combi 105HE boiler fault on the heating side?

I have a Baxi 105HE combi boiler. When the hot water is in demand the boiler will run ok no matter how many t... [Read more]
Mend baxi 105he boiler
2

Baxi 105HE Heating fault?

I have a Baxi 105HE combi boiler. When the hot water is in demand the boiler will run ok no matter how many t... [Read more]
Mend boiler PCB intermittent
3

baxi solo 2 50pf only fires up occassionally?

I have a baxi solo 2 50pf which only fires up occassionally. The "boiler on" light comes on but nothing else a... [Read more]
Mend boiler heating fault
1

Baxi Genesis 80 - What's the fault?

Sometimes it works properly but most of the time on DHW it ignites, burns for a very short time (1 or 2 second... [Read more]
Mend heating pcb flame failure
3

how can i fix my baxi 80 eco?

baxi 80 eco will not light. flame failure light does not light but The system seems to be going through its... [Read more]
Mend boiler heating pcb
10

Baxi Solo 50/4 Wall Mounted PF Burner Shutdown Problem?

My Baxi Solo 50/4 Wall Mounted PF gas fired central heating boiler ignites when the thermostat calls for heat,... [Read more]